Xerox 2830 User Manual
Page 2
All measurements were made on products performing within established operating specifications and received
recommended maintenance procedures. Xerox certifies that this product meets or exceeds the applicable standards for
safety and emissions.
www.xerox.com
Reference “About Xerox”
PRODUCT: 2830
PSDS No. 0610
Floor Space Requirements
Weight
(Meters/Feet)
(K Grams / Lbs.)
1.60 x 1.80 (stationary / 8.3 x 5.9
75 / 165
1.42 x 1.47 (movable on stand) / 4.6 x 4.8
Section V - Emission/Exposure Information*
Light Source
Quartz Halogen - Long time viewing may be uncomfortable, but not harmful
Electromagnetic Emissions
FCC:
Class A
VDE:
Class A
Audible Noise
TLV
Run:
55.0 dB (A)
85 dB (A)
Standby
38.0 dB (A)
Impulse:
65.0 db (A)
Ozone
TLV
480 ug/min
0.1 ppm
0.044 ppm (TWA)
0.097 ppm (Peak)
Concentration Based on Customer Simulation Model:
Daily Copy Volume 571 copies/7.5 hours
Room Size
5.0 m
3
1/2 Air Room Change per Hour
Dust TLV
0.01 - 0.3 mg/m
3
(Black)
10 mg/m
3
0.03 - 0.04 mg/m
3
(Red)
0.03 - 0.04 mg/m
3
(Green)
0.0 - 0.012 mg/m
3
(Blue)
Selenium
TLV
0-0.05 ug/m
3
200 ug/m
3
Arsenic
PEL
<0.01 ug/m
3
10 ug/m
3
Tellurium
TLV
0.01 ug/m
3
* TLV (Threshold Limit Value) and PEL (Permissible Exposure Level) respectively set by American Conference of
Government Industrial Hygienists and by Occupational Safety and Health Administration. These levels are considered
maximum exposure permitted to ensure no health hazard. TWA (Time Weighted Average) for a normal eight hour workday.