Permanent Connection

In the case of a permanent connection it is neces-
sary that you install a double pole switch between
the appliance and the electricity supply (mains), with
a minimum gap of 3mm between the switch con-
tacts and of a type suitable for the required load in
compliance with the current electrical regulations.
The switch must not break the yellow and green
earth cable at any point.

This appliance complies with the requirements laid
out in the EEC Directive 76/899.

Voltage 240 V AC: Fuse rating 13amps

See rating plate for further information.

This appliance meets VDE requirements.

Particular regulations of local electricity authorities
must be observed.
This appliance conforms to EEC Directive No. 82/
499/EWG on radio interference.

1

WARNING! Repairs to electrical appliances
must only be carried out by trained personnel.
Improper repairs may lead to serious risks for
the user.

Connecting the appliance to the water
supply

Important:

• This appliance must not be connected to the hot

water supply.

• When connecting the appliance, use only new

hose kits.

• Only connect the appliance to the drinking water

supply. Rain water or water for industrial use may
only be used if it fulfils the requirements of
DIN1986 and DIN1988.

• Do not kink or crush the water inlet hose or drain

hose.

Permitted water pressure

The water pressure must be at least 1 bar (=10N/
cm

2

=0.1MPa), and may be a maximum of 10bar

(=100N/cm

2

=1MPa).

– If more than 10bar: Connect a pressure reduction

valve.

– If less than 1bar: Disconnect the appliance end of

the inlet hose from the solenoid inlet valve and re-
move the flow meter. (In addition remove the filter
using pointed pliers and take out the rubber gasket
behind it.) Replace the filter.