Servicing instructions, Replacing parts, Pilot unit – Yeoman EXE MIDI PR1145 User Manual
Page 17: General, Main burner
17
2.4 Remove the two screws at the back of the firebox and lift
the burner unit clean (see Diagram 3).
AR1442
3
3. PILOT UNIT
3.1 Follow the procedure for removing the main burner (see
Section 2) when the burner is removed from the stove,
remove the aeration cover by undoing the two screws (see
Diagram 4).
AR1443
4
3.2 Remove the lint arrestor by folding the tabs back (see
Diagram 5).
AR1444
5
1. GENERAL
1.1 All main components can be replaced with the stove in
place but it is essential to turn off the gas supply at the
isolation device before proceeding.
For information on the handling and disposal of fire
ceramics please refer to User Instructions, Section 5,
Cleaning the Fire.
ENSURE THE APPLIANCE IS COLD BEFORE STARTING
WORk ON IT.
2. MAIN BURNER
2.1 Turn the gas supply off at the isolation device, remove the
door and place to one side, and carefully remove the
ceramic fuel bed components.
2.2 Remove the cover plate from the bottom of the stove by
undoing the 6mm bolt, and place to one side (see Diagram
1).
AR1449
1
2.3 Disconnect the thermocouple from the gas valve (A) and
remove the ignition lead from the electrode (B). Cut the
cable tie if required, undo the compression nut (C) from the
pilot unit and undo the compression nut on the injector (D)
(see Diagram 2).
AR1441
D
C
B
2
A
SERVICING INSTRUCTIONS
REPLACING PARTS