beautypg.com

Installation preparation document – Xerox 6115 User Manual

Page 2

background image

Installation Preparation Document

(for physical installation of the product only)

Xerox DocuTech 6100/6115/6135


701P43857
June 2005

Please ensure electrical, space, and supplies are available prior to equipment delivery.

Physical requirements

The DocuSP Controller Monitor and Keyboard are designed to
be positioned on top of the DocuTech 61XX printer. The
controller platform is designed to either be mounted in a stand to
the left of the printer, or to be positioned on the floor to the left of
the printer.


Warning: Due to safety requirements, under no circumstances
should the user interface be visually separated from the printer
module. All system installations must enable mobility of the user
interface to within 30” (760 mm) of the printer for service and
customer maintenance actions

.

Environmental Requirements

Min.

Max.

Temperature

50

o

F

85

o

F *

Humidity

30% RH

60% RH

Heat Emission - with
Binder On

22,165

BTU/Hr

14,185 BTU/Hr
(With Vent Kits)

Heat Emission - with
Binder Off

21,265

BTU/Hr

13,609 BTU/Hr
(With Vent Kits)

Power Consumption
Printer/Finisher w/ Binder
On

1,330 Watts

(Standby)

5,890 Watts

(Running)

Power Consumption
Printer/Finisher w/Binder
Off

1,000 Watts

(Standby)

5,630 Watts

(Running)

* The system will inhibit software problems and shut down above 90

o

F

Operating Supplies

Reorder No.

Impressions / Unit

Dry Ink

6R206

220K/Carton at 6%

area coverage

Developer

5R161

750K / Carton

Fuser Agent

8R2955

250K / Bottle

Stitcher Wire

8R1174

32K / Roll

Binder Tape - Black

8R2928

425 Binds / Reel

Binder Tape – White

8R3601

425 Binds / Reel

Binder Tape – Gray

8R3602

425 Binds / Reel

Binder Tape – Blue

8R3603

425 Binds / Reel

Binder Tape – Brown

8R3604

425 Binds / Reel

Binder Tape – Red

8R3824

425 Binds / Reel

The Xerox Supplies Marketing Center, 1.800.822.2200, is available
for ordering Xerox supplies, including paper and other thruput
material.

Network Requirements

The Ethernet interface on the DocuSP controller is a 10/100-
MB/sec twisted pair standard (10BaseT).


The Ethernet connection to the DocuSP controller must be
compatible with the Institute of Electrical and Electronics
Engineers (IEEE) 802.3 standard. (The physical form of this
connecter is RJ45 and must be correctly wired.)

The DocuSP controller supports TCP-IP, SPX,/IPX, and
EtherTalk Link Access Protocol (ELAP) protocols if the proper
gateways are installed on the controller.

The DocuSP controller does not provide Novell Server network
services. To use the SPX/IPX protocol, a Novell server installed
on the network is required.

A Xerox Token Ring solution is available for the 61XX family.
When Token Ring is installed, it becomes a Token Ring only
connectivity solution. The NetWare gateway and AppleTalk
gateway will not function, and the built in Ethernet bge0 twisted
pair interfaces are disabled. (Gigabit Ethernet is supported with
a Sun controller card – some customers have asked for this
option.)

Telephone Requirements

A voice telephone line is required where the DocuTech 6100, 6115,
6135, is installed.
Voice line will be used when the operator, administrator, or Xerox
Service Personnel is asked to read the screen information from the
DocuSP controller dialogs to Xerox Customer Support or Technical
Support Center Personnel.

Position / Performance at Maturity

Average
Monthly
Service
Calls

8

7

6

5

4

3

2

1

Average Monthly Copy Volume

300K

1M

2M

Optimum Range

500K

1.5M

Note:
This product is targeted for the 300K to 2M copies per month market
segment. Usage above this range may result in a higher service
frequency