York F*FP User Manual
Page 8

295421-YTG-B-0707
8
Unitary Products Group
ELECTRICAL DATA - 1
∅ - 208/230 - 1-60
Models
Heater
1
Model
1. 0 or as follows: 0 = No Breaker, 1 = Breaker.
MAX. STATIC
& MIN. CFM
Total Heat
2
2. See Conversion Table below:
KW Staging
3
3. If first stage heat or 66 is connected to W1, otherwise refer to this table.
KW
MBH
W1 Only
W2 Only
W1 + W2
Static
Tap
208V
240V
208V
240V
208V
240V
208V
240V
208V
240V
F4FP024H06T2*
2HK*6500506B
0.5
Low
3.8
5.0
13.0
17.1
3.8
5.0
3.8
5.0
3.8
5.0
2HK*6500806B
Low
5.6
7.5
19.1
25.6
3.8
5.0
5.6
7.5
5.6
7.5
2HK*6501006B
Low
7.5
10.0
25.6
34.1
3.8
5.0
7.5
10.0
7.5
10.0
F4FP030H06T2*
2HK*6500506B
0.5
Low
3.8
5.0
13.0
17.1
3.8
5.0
3.8
5.0
3.8
5.0
2HK*6500806B
Low
5.6
7.5
19.1
25.6
3.8
5.0
5.6
7.5
5.6
7.5
2HK*6501006B
Low
7.5
10.0
25.6
34.1
3.8
5.0
7.5
10.0
7.5
10.0
2HK16501506B
High
11.3
15.0
38.6
51.2
3.8
5.0
7.5
10.0
11.3
15.0
F4FP036H06T2*
2HK*6500506B
0.5
Low
3.8
5.0
13.0
17.1
3.8
5.0
3.8
5.0
3.8
5.0
2HK*6500806B
Low
5.6
7.5
19.1
25.6
3.8
5.0
5.6
7.5
5.6
7.5
2HK*6501006B
Low
7.5
10.0
25.6
34.1
3.8
5.0
7.5
10.0
7.5
10.0
2HK16501506B
Med
11.3
15.0
38.6
51.2
3.8
5.0
7.5
10.0
11.3
15.0
2HK16501906B
4
4. 2HK16501906B only applies to F4FP036 Model.
High
13.2
17.6
45.1
60.1
2.8
3.8
10.4
13.8
13.2
17.6
F4FP040H06T2*
2HK*6500506B
0.5
Low
3.8
5.0
13.0
17.1
3.8
5.0
3.8
5.0
3.8
5.0
2HK*6500806B
Low
5.6
7.5
19.1
25.6
3.8
5.0
5.6
7.5
5.6
7.5
2HK*6501006B
Low
7.5
10.0
25.6
34.1
3.8
5.0
7.5
10.0
7.5
10.0
2HK16501506B
High
11.3
15.0
38.6
51.2
3.8
5.0
7.5
10.0
11.3
15.0
F4FP042H06T2*
2HK*6500506B
0.5
Low
3.8
5.0
13.0
17.1
3.8
5.0
3.8
5.0
3.8
5.0
2HK*6500806B
Low
5.6
7.5
19.1
25.6
3.8
5.0
5.6
7.5
5.6
7.5
2HK*6501006B
Low
7.5
10.0
25.6
34.1
3.8
5.0
7.5
10.0
7.5
10.0
2HK16501506B
Low
11.3
15.0
38.6
51.2
3.8
5.0
7.5
10.0
11.3
15.0
F4FP045H06T2*
2HK*6500506B
0.5
Low
3.8
5.0
13.0
17.1
3.8
5.0
3.8
5.0
3.8
5.0
2HK*6500806B
Low
5.6
7.5
19.1
25.6
3.8
5.0
5.6
7.5
5.6
7.5
2HK*6501006B
Med
7.5
10.0
25.6
34.1
3.8
5.0
7.5
10.0
7.5
10.0
2HK16501506B
High
11.3
15.0
38.6
51.2
3.8
5.0
7.5
10.0
11.3
15.0
F5FP048H06T2*
2HK16500506B
0.5
Med-Low
3.8
5.0
13.0
17.1
3.8
5.0
3.8
5.0
3.8
5.0
2HK16500806B
Med-Low
5.6
7.5
19.1
25.6
3.8
5.0
5.6
7.5
5.6
7.5
2HK*6501006B
Med-Low
7.5
10.0
25.6
34.1
3.8
5.0
7.5
10.0
7.5
10.0
2HK16501506B
Med-Low
11.3
15.0
38.6
51.2
3.8
5.0
7.5
10.0
11.3
15.0
2HK16502006B
Med-Low
15.0
20.0
51.2
68.3
3.8
5.0
11.3
10.0
15.0
20.0
2HK16502506B
Med-Low
18.8
25.0
64.2
85.3
3.8
5.0
11.3
15.0
18.8
25.0
F5FP060H06T2*
2HK*6501006B
0.5
Med
3.8
5.0
13.0
17.1
3.8
5.0
3.8
5.0
3.8
5.0
2HK16500806B
Med
5.6
7.5
19.1
25.6
3.8
5.0
5.6
7.5
5.6
7.5
2HK16501006B
Med
7.5
10.0
25.6
34.1
3.8
5.0
7.5
10.0
7.5
10.0
2HK16501506B
Med
11.3
15.0
38.6
51.2
3.8
5.0
7.5
10.0
11.3
15.0
2HK16502006B
Med
15.0
20.0
51.2
68.3
3.8
5.0
7.5
10.0
15.0
20.0
2HK16502506B
Med
18.8
25.0
64.2
85.3
3.8
5.0
11.3
15.0
18.8
25.0
F4FV060H06T2*
2HK*6500806B
0.5
1335
5.6
7.5
19.1
25.6
3.8
5.0
5.6
7.5
5.6
7.5
2HK*6501006B
1335
7.5
10.0
25.6
34.1
3.8
5.0
7.5
10.0
7.5
10.0
2HK16501506B
1335
11.3
15.0
38.6
51.2
3.8
5.0
7.5
10.0
11.3
15.0
2HK16502006B
1335
15.0
20.0
51.2
68.3
3.8
5.0
7.5
10.0
15.0
20.0
2HK16502506B
1335
18.8
25.0
64.2
85.3
3.8
5.0
11.3
15.0
18.8
25.0
NOTE: All models available with factory installed horizontal drain pan.
KW & MBH CONVERSIONS - FOR TOTAL POWER INPUT REQUIREMENT
FOR
230V
OPERATION MULTIPLY
240V
TABULATED KW & MBH BY
.918