beautypg.com

Roubleshooting, Unit, House – X10 Wireless Technology MK19A User Manual

Page 24: Continuous momentary, Unit house

background image

47

46

 T

ROUBLESHOOTING

The Transceiver Module doesn’t

respond to the remote:
• Check the House Code of the

Transceiver Module is set to A. If you

have changed the Housecode on the

remote (see p. 43), check that it

matches the Housecode on the

module.

• Press the ON/OFF button on the

front of the Transceiver Module to

confirm it operates the equipment

connected to it.

The Transceiver Module works, but

other modules don’t respond:
• Check that the module has the same

Housecode as the Transceiver

Module.

• Try plugging the Module into a

different outlet.

The Mouse Remote won’t control your

A/V equipment, or doesn’t work at all:
• Use manual controls or the original

remote control to confirm the

equipment is working properly.

• Be sure you pressed the device key

for the device you want to control.

• Re-enter the code for your A/V

product from the code listings on

pages 23 through 32.

• Try searching for the code as

described on page 34.

• Replace the Mouse Remote’s

batteries.

The Remote won’t control my audio CD

player:
• The CD key on the Mouse Remote

controls the CD player in your PC. To

control an external audio CD player

set it up under the AUX key. Press

Setup, then AUX, then CD, then enter

the code from the code listings under

the heading CD Codes (page 30-

31).

Plug in a Heavy Duty Module

HD245 to control 220V appliances

such as air conditioners and water

heaters.

A

I

E

M

O

C

G

K

1

9

5

13

15

3

7

11

UNIT

Remote Chime

HOUSE

ON

OFF

RF Wall Switch

BRIGHT

DIM

ON

ON

2

1

1

9

5

13

A

I

E

M

A

B

1

2

3

INPUT

MODE

POWERFLASH INTERFACE

TEST

ALL UNITS OFF

1

9

5

13

A

I

E

M

CONTINUOUS

MOMENTARY

UNIVERSAL MODULE

ON

OFF

SOUNDER & RELAY

RELAY ONLY

SOUNDER ONLY

A

I

E

M

1

9

5

13

Heavy Duty

Appliance Module

UNIT

HOUSE

Use a controller to trigger the

Remote Chime Module SC546 to

call Dad up for dinner, or warn

people you’re about to turn on the

sprinkler.

Fit a Wireless Wall Switch

RW724 anywhere you need an

extra switch - with no wires.

Sends commands to the

Transceiver Module just like a

remote.

Use the isolated contacts on the

Universal Module UM506 to control

pool pumps, sprinklers, drapes and

other low voltage equipment.

Includes built in warning beeper.

Switch entrance or garage lights on

from your car with the convenient

Keychain Remote KC674.

The PowerFlash Module PF284

connects to dry contact or low

voltage alarm terminals on your

burglar alarm system and flashes

X-10 controlled lights when it is

triggered.

Use the Mini Timer MT10A

to program up to 4 X-10

Modules to go on and off

up to twice a day.