TECHNICAL DATA

Table no.1

TABLE N°1: Adaption to various types of gas

APPLIANCE CATEGORY:

II

2H3+

Burner Types

of

Gas

Pressure Nozzle

Diameter

Rater Capacity

Reduced

Capacity

by-pass Diameter

Mbar

1/100

mm.

g/h l/h kw kcal/h kw Kcal/h 1/100

mm.

Natural G20

20

72

-

95

1

860

0,48

413

34

Auxiliary

Butane G30 28

50

73 - 1 860 0,48 413

34

Propane

G31

37

50

71

-

1

860

0,48

413 34

Semi-

Natural G20

20

97

-

167

1,75

1505

0,6

516

36

rapid

Butane G30

28

65

127

-

1,75

1505

0,6

516

36

Propane

G31 37

66

125 - 1,75 1505 0,6 516

36

Natural G20

20

115

-

286

3

2580

1,05

903

52

Rapid

Butane G30

28

85

218

-

3

2580

1,05

903

52

Propane

G31

37

85

214

-

3

2580

1,05

903 52

Double

Natural G20

20

135

-

334

3,5

3010

1,8

1548

65

Ring

Butane G30

28

95

254

-

3,5

3010

1,8

1548

65

Propane

G31 37

95 250 - 3,5 3010 1,8 1548

65

INSTALLATION

Positioning

Remove all the packaging and install the cooker
in a dry, ventilated room not near curtains,
paper, alcohol, petrol etc.

The appliance must be set on a heatproof, level
floor.

This appliance is approved to class “Y”
(EN60335-2-6 plus subsequent amendments).
This means that the appliance can be installed
up against a wall with a distance of not less than
20mm (fig 2) or inserted between 2 walls (fig 1).
Only one side wall can exceed the height of the
work surface and it must have a distance of
70mm from the edge of the cooker.

Any walls of the adjacent kitchen furniture and
the wall behind the cooker must be made with
heat resistant material that can withstand a
minimum overtemperature of 65K.

Any overhanging cabinetry installed above the
work surface must be located at a distance of no
less than 700mm.