beautypg.com

Electrical connections, Supply cable specifications – Zanussi ZCE 650 User Manual

Page 31

background image

31

Electrical connections

Any electrical work required to install this hob
should be carried out by a qualified electrician or
competent person, in accordance with the current
regulations.

THIS COOKER MUST BE EARTHED.

The manufacturer declines any liability should
these safety measures not be observed.

This cooker is designed to be connected to a
230 V 50 Hz AC electrical supply.

Before switching on, make sure the electricity supply
voltage is the same as that indicated on the hob rating
plate. The rating plate is located on the bottom of the
hob. A copy is attached on the back cover of this book.

The cooker is supplied without supply cord. A 3 core
flexible supply cord must be fitted, in accordance with
the specification given in the relevant tables.

1) Loosen the two fixing screws securing the back

protective screen of the cooker, then lift it up
and remove it. This will expose the terminal
block on the right bottom corner.

2) Loosen the two cable clamp screws and lift

the top section of the clamp enough to allow
the cable to be passed through.

3) Connect the red (live) wire to the terminal which

is marked with the letter "L".

4) Connect the black (neutral) wire to the terminal

which is marked with the letter "N".

5) After fitting a green or yellow/green sleeve over

the bare copper wire (earth wire), connect the
exposed end to the terminal which is marked
with the earth symbol

or with the letter

"E"coloured green and yellow.

NOTE:

The earth wire should be about 2 cm. longer
than the live and neutral wires.

6) Secure the cable by means of the clamp

screws and refit the back protective screen.

The cooker should be connected to a double pole switch
with a minimum gap of 3 mm. between the switch
contacts and of a type suitable for the required load in
compliance with the current electric regulations. The
switch should be sited within 2m of the hob and be easily
accessible upon completion of the installation.

The switch must not break the yellow and green earth
cable at any point.

Ensure that the hob supply cord does not come
into contact with surfaces with temperatures
higher than 50 deg. C.

FO 2375

Supply Cable Specifications

Connection Min. size

Cable / flex Fuse

via

Cable/flex type

• Cooker

6 mm

2

H05 VV-F

30 A

Control

Circuit

For Uk use only

For Europe use only

Min. size Cable/flex Cable / flex type Fuse

3x 2.5 mm

2

H05 RR-F

30 A

H05V2V2-F