beautypg.com

Zebra Technologies 600 User Manual

Page 49

background image

Symptom

Diagnosis

Action

Changes in parameter

settings did not take

effect.

Parameters are set

or saved

incorrectly.

Reload the factory defaults (see

“FEED Key and PAUSE Key” later in

this chapter), calibrate the printer,

then cycle the power on/off switch.

If problem

continues, there

may be a

problem on the

main logic board.

Call a service technician.

When using wide ribbon

(over 2.4"), the image

gets lighter or smears

near the end of the roll

of ribbon. Ribbon

appears to slow down or

stop.

Too much

back-tension on

the ribbon.

See “Loading the Ribbon” in

Getting Ready to Print to adjust the

ribbon supply spindle to provide

low tension.

ZPL was sent to printer,

but not recognized. The

DATA LED remains off.

Communications

parameters are

set incorrectly.

Print configuration label and verify

that the host computer and printer

settings match. If they do, perform

the MODE key self test and check

for format or overrun errors. If

they do not, refer to

“Communicating with the Printer”

in Getting Ready to Print.

Prefix and

delimiter

characters set in

printer

configuration do

not match the

ones sent in the

ZPL label formats.

Set the characters in the printer to

match the ZPL format.

Check configuration printout for

correct characters.

If problem continues, check the

ZPL format for changed ^CC,

^CT, and ^CD instructions.

S400 & S600 User’s Guide