MAINTENANCE and SERVICING

7.6 Fit only Yeoman ceramic glass, which is suitable to use in

high temperature applications.

7.7 Using the stove with a damaged door glass could cause

dangerous fumes to enter the room, or the stove to overfire,

resulting in damage.

8. FITTING A NEW DOOR SEAL

8.1 To maintain the safe use of your stove you may need to

replace a damaged or worn door sealing rope. To complete

this operation, use this method.

8.2 Remove the door from the stove, by opening and lifting the

door free of the hinge blocks. Then lie the door face down

on a soft flat surface, to protect the paintwork and glass.

PR7530

Joint

Seal 14mm

1 Door

PR7531

Seal 12x3

Seal 14mm

2 Door

8.3 Remove the old rope and scrape old glue from the locating

grooves. Clean the locating groove with a clean dry cloth to

remove all old dust and debris.

8.4 Squeeze a generous bead of fresh Thermic Seal glue into

the rope locating groove (Part no. 5037). Press the new

Stovax rope into the locating groove, placing the joint in the

middle of the lower edge of the door.

8.5 Refit the door and close the door to apply pressure to new

rope. Leave the stove closed for at least 12 hours before

lighting the stove and using at a low output for

approximately one day.

8.6 Using the stove with a damaged door seal could cause

dangerous fumes to enter the room, or the stove to overfire,

resulting in damage.

If you require help, your local Yeoman dealer will be able

to carry out all of your service and maintenance

requirements for a reasonable cost.

9. ADJUSTING DOOR CATCH

(ALL MODELS)

9.1 To adjust the fit of the door catch rotate the door knob

clockwise to loosen the fit or anti-clockwise to tighten the
fit. This adjustment should be made in steps of one full turn
of the door knob. The flat edge of the door cam should be
parallel with the door opening on the stove body when the
door is open.

Your retailer will also be able to provide genuine spare parts such

as replacement glass, door sealing rope and fire bricks, as and

when required. Remember, an annual service is recommended to

keep your appliance in best possible condition.

To help you get the best performance from your stove and keep it

in good condition, inside and out, we offer a wide range of

cleaning and maintenance

products as well as a host of

accessories to help you

enjoy the maximum

pleasure from your stove.

Your Yeoman retailer will be

able to provide full details

but here is a brief list of

items that may be of

interest:

Product

Code

Description

3047

Extra long matches

5039

Gas lighter

4052

Log basket

3048

Wood sling - for easy carrying of logs

3016

Log tongs

4027

Extra long protective gloves

3046

Stove pipe thermometer

5038

Ash caddyHearthgate - 5 section
(for areas 1780x610mm)

5044

Ash caddyHearthgate - 7 section
(for areas 1780x405mm)

4227

Ash caddy

4228

Ash caddy

2091

Ashclean vacuum cleaner attachment

4232

Steel brush

CARE OF YOUR STOVE

This manual is related to the following products: