Pressure testing, Checking the grill, Checking the hotplate – Zanussi ZCG 7691 User Manual
Page 42: Checking lid shut-off device
42
Mark off dimension 'B' (see Fig.3a) back
from this line on the centre line of the
bracket to locate the front edge of the
lower bracket. Fix lower bracket (with
two fixing holes) to the floor then
measure the height from floor level to
engagement edge on back of appliance,
dimension 'C' of Fig. 3b.
4. Assemble upper bracket to lower bracket
so that the underside of bracket is
dimension 'C' + 3mm above floor level.
(See Fig. 3b)
Reposition appliance and check that top
bracket engages into appliance back as
shown in Fig. 3b.
Pressure testing
1. The oven injector is used as a pressure
test point.
Remove the oven furniture. Remove
oven burner box retaining clips (one
spring clip from each side) and remove
box front cover. Replace one clip back
into the right hand side of the burner
box.
Remove oven burner by removing the
spring clip from the right hand side of
the oven burner and slide burner
off
injector, whilst easing it forward and
taking care not to strain the F.S.D.
phial.
2. Connect the pressure gauge to the
oven injector.
3. Check the supply pressure by turning
the thermostat on and one hotplate tap
full on and light the appropriate burner.
The pressure should be either:-
(i)
For Natural Gas 20mbar
(ii)
For LP. Gas. The pressure must
be set to 28 mbar for use on
butane or 37 mbar for use on
propane.
4. Turn off the taps, disconnect the
pressure gauge and replace oven burner
and cover, ensuring that the F.S.D phial
is correctly located into the bracket on
the burner.
5. Check operation of the oven.
Checking the grill
Place the grill pan containing the grid, with
the handle attached, into the grill
compartment. Light the grill burner by
turning the grill tap full on and pressing the
ignition button on the fascia panel. As soon
as the burner is lit the button can be
released.
Checking the hotplate
Lift the lid. Fit the burner crowns and caps
ensuring that they are correctly seated. Fit
the pan supports.
To light the hotplate burners push in and
hold the control knob, turn to large flame
symbol (highest setting) and press the
ignition button immediately. Keep the
control knob depressed for up to 5 seconds,
but no longer than 10 seconds. After this
time release the controls. The flame should
remain alight.
Turn off the hotplate and wait 1 minute.
Turn the hotplate control knob to large flame
symbol (highest setting). DO NOT depress
or attempt to ignite the burner. No gas
should flow.
Checking lid shut-off device
1. Lift the lid
2. Turn one hotplate tap to its full on
position and push the ignition button.
3. Close the lid. There should now be no
gas supply to the hotplate and the
burner will go out.
4. Turn off the hotplate and lift the lid. The
gas supply should now be restored to
the hotplate, when the tap is turned on.