Levelling the appliance, Connecting to electricity supply – Zanussi ZCG 7691 User Manual

Page 39

background image

39

For appliances installed in the Republic of

Ireland please refer to NSAI-Domestic Gas

Installation IS813 Current Edition Section7

Permitted Locations of appliance Table4---

Locations and Permanent Ventilation

requirements-flueless appliances.

Note: - L.P.G. cookers MUST NOT be

installed below ground level i.e. in a

basement or aboard any boat, yacht or other

vessel.

Levelling the appliance

Adjustment to suit floor conditions or height

is obtained by rotating clockwise or anti

clockwise the feet at the front and rear of the

appliance. A spirit level should be placed on

one of the shelves to confirm the appliance

is correctly levelled.

Connecting to electricity

supply

Warning: This appliance must be

earthed.

Do not earth this appliance to the

gas supply piping.

Connect to 230-240 A.C supply

only.

Connection to the electricity supply should

be made via a properly earthed, readily

accessible wall socket. Which is adjacent to,

but not directly above and not more than

1.7m away from the appliance and capable

of electrical isolation. The cooker point

should be within 1.7m of the appliance to

make it accessible to switch off the

appliance in case of emergency. The mains

lead should be routed so that it cannot touch

hot parts of the cooker i.e. the back panel

above a height of 650mm from the floor.

Should this plug not fit the socket outlet in

your home it should be cut off and replaced

with a suitable plug as outlined below.

If the moulded plug is cut from the cable

for any reason it must be destroyed or

disposed of safely, as protruding wires

will be an electrical shock hazard.