DIMENSIONS

Height

878 mm.

OF RECESS

Width

560-570 mm.

Depth

550 mm.

DIMENSIONS

Height

320 mm.

OF THE

Width

420 mm.

MAIN OVEN

Depth

390 mm.

CAVITY

Oven capacity 53.2 litres

DIMENSIONS

Height

185 mm.

OF THE

Width

420 mm.

LOWER OVEN

Depth

400 mm.

CAVITY

Oven capacity 31 litres

Upper oven ratings
Fan Oven element

2.08 kW

Grill element

1.82 kW

Convection Fan

30 W

Oven Light

15 W

Cooling Fan

25 W

Total Rating

2.15 kW

Lower oven ratings
Oven element (top+bottom)

1.89 kW

Grill element

1.82 kW

Oven Light

15 W

Total Rating

1.93 kW

Total connected load

4.055 kW

Electrical Connection

The oven is designed to be connected to 230-240V

(50Hz) electricity supply.

The oven has an easily accessible terminal block

which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

or E

-

Earth terminal

THIS OVEN MUST BE EARTHED

The cable used to connect the oven to the electrical

supply must comply to the specifications given

below.

It is necessary that you install a double pole switch

between the oven and the electricity supply (mains),

with a minimum gap of 3mm between the switch

contacts and of a type suitable for the required load

in compliance with the current rules.

The switch must not break the yellow and green

earth cable at any point.

Important

After installation and connecting, the cable must be

placed so that it cannot at any point reach a tempe-

rature of more than 60°C above the ambient tem-

perature.

Before the oven is connected, check that the main

fuse and the domestic installation can support the

load; and that the power supply is properly earthed.

The manufacturer declines any responsibility should

these safety measures not be carried out.

This oven must be installed by

qualified personnel to the relevant

British Standards.

The oven must be installed according to

the instructions supplied.

Installation

Connection Min. size Cable/flex Fuse

via

Cable/flex type

• Cooker

6 mm

2

PVC/PVC 30 A

Control

twin and

Circuit

earth

For Uk use only

For Europe use only

Min.size Cable/flex Cable / flex type Fuse
4 mm

2

H05 RR-F

30 A