Chapter 11 Troubleshooting

73

11.6 Problems with the Web Configurator

11.7 Problems with Telephone or Telephone Port

Table 32 Troubleshooting the Web Configurator

PROBLEM

CORRECTIVE ACTION

I cannot access the

web configurator.

Also

see Table 31

.

Your computer’s and the Prestige’s IP addresses must be on the same subnet.
Your computer’s IP address must be on the same subnet as the Prestige’s

Ethernet IP address or management IP address (whichever you want to use to

access the Prestige).
If the Prestige’s Ethernet IP address or management IP address has changed,

then enter the new one as the URL.
If you have switched from managing one Prestige 2002 to another, your

computer’s ARP (Address Resolution Protocol) table may contain an entry that

maps the management IP address to a different Prestige 2002’s MAC address).
In Windows, use arp -d at the command prompt to delete all entries in your

computer’s ARP table. Otherwise, you can use arp -d inet_addr [if_addr]

(where if_addr is the Prestige 2002’s management IP address) to remove just the

entry for the Prestige 2002’s management IP address.

I access the wrong

Prestige 2002 when

using the

management IP

address to access

the Prestige 2002.

This problem may occur if you have more than one Prestige 2002 on the same

LAN. Disconnect your Prestige 2002 from the network and connect directly

through the Prestige 2002’s PC port. You may also need to delete your

computer’s ARP table entry for the Prestige 2002’s IP address (see above).

Table 33 Troubleshooting Telephone

PROBLEM

CORRECTIVE ACTION

The telephone port

won’t work or the

telephone lacks a

dial tone.

Check the telephone connections and telephone wire.
Make sure you have the VoIP screen properly configured.