Position the air conditioner cabinet – Whirlpool ACE082XP1 User Manual
Page 7
7
Option 2—Plaster wall with no molding
If the plastered wall is to be flush with the cabinet and no molding
is used, the wood frame must be set
¹⁄₂" (13 mm) into the inside
wall.
1. Construct wood frame. See “Location Requirements” for
dimensions.
2. Measure outside width and height of frame to determine wall
opening dimensions.
3. Cut opening through the wall. Remove and save insulation.
NOTES:
■
Dimension for depth depends on wall thickness and type
of molding.
■
Do not block louvers in air conditioner cabinet.
■
Use 1" (2.5 cm) or heavier lumber for wood frame.
4. Apply wood preservative to the outside exposed surface.
5. Insert the frame in the wall opening. Square and level frame.
6. Attach frame securely to the wall.
Position the Air Conditioner Cabinet
■
Handle air conditioner with care.
■
Be sure your air conditioner cabinet does not fall out of the
opening during installation or removal.
■
The place where the power cord exits the air conditioner
should be no more than 4 ft (122 cm) from a grounded
3 prong outlet.
■
Do not block the louvers on the front panel.
■
Do not block the louvers on the outside of the air conditioner.
Window installation (on some models)
1. Center empty cabinet in window. Check that lower rail of air
conditioner cabinet is behind and against back side of
windowsill. Maintain a firm hold on the air conditioner
cabinet. Lower window sash to hold cabinet in place.
2. Measure the distance between the right-hand side of the
cabinet and the inside of the window channel.
3. Repeat for the left side. Adjust the cabinet until the distance
on each side is the same.
4. Check that air conditioner cabinet is tilted to the outside so
that water will run to the outside.
5. Pull left-hand curtain out until it fits into window channel. Use
a
³⁄₃₂" drill bit to drill a starter hole through the hole in the
curtain housing and into the lower window sash.
Front View
A. Plastered wall
B. Inside wall
C. Wood frame
D. Louvers
A. Outside width
B. Outside height
C. Depth
D
A
C
B
A
B
C
A. Window sash
B. Empty cabinet
C. Window channel
A. Left-hand curtain
B. Window channel
B
A
C
A
B