3 quick install – WiebeTech SS8 User Manual
Page 14
W i e b e T e c h L L C
4.3 Quick install
Use the
Quick install
function to create a volume easily.
Step 1: Select
Quick install
then choose the RAID Level desired. After
choosing the RAID level, click
. It will take you to step 2 for
Bus ID
,
SCSI ID
, and
LUN
setup.
Step 2: In this step, the volume can be customized as needed.
Volume size, Bus
ID
,
SCSI ID
, and
LUN
can be assigned specified numbers to be attributed to the
volume. The maximum volume size is shown as default. The volume can only be
less or equal to the number shown. By default, the
Bus ID
,
SCSI ID
, and
LUN
are
set at 0. These numbers can be changed by the pull down menu. Click
after desired volume size and IDs are set.
Note
Other UDVs can be created by Quick Install. The remaining capacity
from the Volume Group will be shown and the controller will determine
the next ID settings to avoid conflicts with other UDVs.
Step 3: Confirm page. Click
if all settings are correct.
Done: A summary page with the User data volume will be shown as Figure 4.3.1.
Figure 4.3.1
(Figure 4.3.1: A RAID 0 user data volume with the UDV name “QUICK14183”, named by the
system itself, with the total available volume size 227840MB, or roughly 230GB.)
ProSATA SS8 User Manual
- 14 -