beautypg.com

Installation, Lgb-6 to lgb-20, Series 2 – control supplement – Weil-McLain LGB-20 User Manual

Page 2

background image

LGB-6 to LGB-20

Series 2 – Control Supplement

2

Part Number 550-141-815/1010

Boiler

Number

Flame Sensor *

Pilot Burner *

Boiler

Number

Flame Sensor *

Pilot Burner *

No. 1

No. 2

No. 1

No. 2

No. 1

No. 2

No. 1

No. 2

LGB-6

2

---

9

---

LGB-14

2

16

13

25

LGB-7

2

---

11

---

LGB-15

2

16

13

27

LGB-8

2

---

13

---

LGB-16

2

18

15

29

LGB-9

2

---

15

---

LGB-17

2

18

15

31

LGB-10

2

---

16

---

LGB-18

2

20

16

33

LGB-11

2

---

16

---

LGB-19

2

20

16

34

LGB-12

2

---

16

---

LGB-20

2

22

16

36

LGB-13

2

1`4

11

23

* From left burner.

Boiler

Number

7.00”
W.C.
Carton

Inlet Pipe Size

5.00”
W.C.
Carton

Inlet Pipe Size

Left Base

Right Base

Left Base

Right Base

LGB-6

A and B

1”

---

A and B

1-¼”

---

LGB-7

A and B

1”

---

A and B

1-¼”

---

LGB-8

C and D

1”

---

C and D

1-¼”

---

LGB-9

C and D

1”

---

C and D

1-¼”

---

LGB-10

E, F and G

1-¼”

---

E

1-½”

---

LGB-11

E, F and G

1-¼”

---

F and G

2”

---

LGB-12

E, F and G

1-¼”

---

F and G

2”

---

LGB-13

H

1”

1”

H

1-¼”

1-¼”

LGB-14

I

1”

1”

I

1-¼”

1-¼”

LGB-15

J

1”

1”

J

1-¼”

1-¼”

LGB-16

J

1”

1”

J

1-¼”

1-¼”

LGB-17

J

1”

1”

J

1-¼”

1-¼”

LGB-18

K

1-¼”

1”

K

1-½”

1-¼”

LGB-19

L

1-¼”

1-¼”

M

1-½”

1-½”

LGB-20

L

1-¼”

1-¼”

N

2”

1-½”

I

Installation

1. Assemble pilot burner and flame sensor to main burners with pilot brackets. See Figures

1 and 2 (page 3). Install ground wiring as shown in Figures 1 and 2 (page 3).

2. Reinstall burner assemblies. See Table 1, below for pilot burner and flame sensor loca-

tions.

3. Install gas controls and ignition control panel(s) as shown in Table 2, below and Figure

6 (page 12).

Table 1

Pilot burner and flame sensor

locations

Table 2

Gas control arrangement