Caution

To reduce the potential risk of fire, electrical shock, or injury to persons:

1) All electrical wiring (both installation & repair) must be done by a licensed electrician and in

accordance with local and state ordinances.

2) No modifications, additions or deletions should be made to the pump, without factory

approval.

3) Before stating motor, fill up the tub with water to level recommended by whirlpool

manufacturer. Never run pump dry!

4) Do not relocate pump without prior approval from factory.

Warning

To reduce the risk of injury, do not permit children to use this product unless they are closely

supervised at all times.

To reduce the risk of electric shock, replace damage cord immediately. And do not use extension

cord to connect unit to electric supply; provide a properly located outlet.

TROUBLESHOOTING GUIDE

SYMTOMS

PROBABLE CAUSES

RECOMMENDED ACTION

Pump will not turn on No power to motor

Check switch, fuse or breaker, also

connection from motor to switch

Pump runs slow

Pump not wired same as

voltage supplied

Check pump to connect voltage