beautypg.com

Manual advance diagnostics --- model whes30 – Whirlpool WHES20 User Manual

Page 32

background image

32

4. Press the

RECHARGE button to move the softener into fast rinse. Again look for a fast drain

flow. Allow the softener to rinse for a few minutes to flush out any brine that may remain in the

resin tank from the brining cycle test.

5. To return the softener to service, press the

RECHARGE button.

Manual Advance Diagnostics --- Model WHES30

Use the following procedures to advance the water softener through the regeneration cycles to check

operation.
Lift off the salt hole cover, remove the top cover by unlocking the tabs in the back and rocking forward,

to observe cam and switch operation during valve rotation.
1. Press and hold

PROGRAM for 3 seconds until 000 -- -- shows in the display.

2. The first 3 digits indicate water meter operation as follows:

000 (steady) = Soft water not in use, and no flow through the meter.
Open a nearby soft water faucet.
000 to 199 (continual) = Repeats display for each gallon of water passing through the meter.

NOTE:

If you don’t get a reading in the display, with faucet open, pull the sensor from the valve

outlet port. Pass a small magnet back and forth in front of the sensor. You should get a

reading in the display. If you get a reading, unhook the in and out plumbing and check the

turbine for binding.

3. Symbols in the display indicate POSITION switch operation.

Switch is open

(cam not rotating)

Switch is closed

(Cam rotating)

4. Use the

RECHARGE button to manually advance the valve into each cycle and check correct

switch operation.

NOTE:

Be sure water is in contact with the salt, and not separated by a salt bridge... see “Breaking

A Salt Bridge” section.

5. While in this diagnostic screen, the following information is available and may be beneficial for

various reasons. This information is retained by the computer from the first time electrical power

is applied to the face plate.

Press

+

Up to display the number of days this electronic control has had electrical

power applied.