Maximum Days Between Regenerations

The water softener automatically controls regeneration frequency. This provides the greatest operating

efficiency, and under most conditions, this feature should be left in this mode. However, modify this

feature if you want to force a regeneration every set number of days. For example, if your water supply

contains iron and you want the softener to regenerate at least once every few days to keep the resin

bed clean, set the display as shown below. Setting is available from 1 to 15 days by using the UP and

DOWN buttons.

NOTE:

The softener will recharge on its own if needed, even if it is before the set number of days.

1. Press and hold the

PROGRAM button until the following screen is displayed.

Once in this display, press the

PROGRAM button four times and following display is shown.

2. Press the

+

Up or

Down buttons to set number of days.

12 or 24 Hour Clock

All time displays are shown in standard clock time (1 to 12 PM; and 1 to 12 AM) at the 12 hr default

setting. If 24 hour clock displays are desired, follow steps below.
1. Press and hold the

PROGRAM button until the following screen is displayed.

Once in this display, press the

PROGRAM button five times and the following display is

shown.

12 Hour Clock Initiated

24 Hour Clock Initiated

2. Press the

+

Up or

Down buttons to set clock.