Configuration Menu

Menu Screen

Number

Displayed

(Factory Default)

Press

or

to select options

01

(SS)

HP

Select Single Stage (SS) or
Heat Pump (HP) for a single compressor

02

Sleep

(OFF)

On

Select Sleep Timer On or OFF
If selected OFF, skip to menu screen 04

03

h

(8)

1 to 12

Select 1 to 12 hours for Sleep Timer On.
See Sleep Timer section on page 3

04

CS

(OFF)

On

Select Cool Savings Feature On or OFF
If selected OFF, skip to menu screen 06

05

CS

(3)

1 to 6

Select 1 to 6 for Cool Savings Feature On
See Cool Savings section on page 3

06

CR

(ME)

FA, SL

Select Adjustable Anticipation, cycle rate for Heat
See table below

07

CR

(ME)

FA, SL

Select Adjustable Anticipation, cycle rate for Cool
See table below

08

CL

(OFF)

On

Select Compressor Lockout OFF or On. When selected On,
the thermostat will wait 5 minutes before turning the
compressor on.

09

L

(On)

OFF

Select Display Light On of OFF. When selected On and the “C”
terminal is connected, the backlight will stay on continuously.
When OFF the backlight will come on for a short time when any
key is pressed.

10

Room Temp

(0)

4 LO to

4 HI

Select room temperature display for 4

o

higher or 4

o

lower than

the actual temperature

11

o

F

o

C

Select

o

F or

o

C Display (temperature displayed in Fahrenheit or

Celsius)

12

Change Filter

(OFF)

On

Select filter maintenance indicator OFF or On.
If selected OFF, item B will be skipped

13

Change Filter

(200 h)

25 to 1975

Select 25 to 1975 hours for Change Filter reminder
See Change Filter reminder section on page 3

Menu Navigation

Press

for next. Press

to go back

To exit the menu: Set the system switch to Cool or Heat. If
no keys are pressed within fifteen minutes, the thermostat will
revert to normal operation.

Installation

Select Configuration Options

The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements.

Select Cycle Rate – The cycle rate can be adjusted to keep
the heat or cool on longer or shorter to match the temperature
response of the home with your heating and cooling system.

MODE

Fast

Medium

Slow

(FA)

(ME)

(SL)

SS Heat

0.6

o

F

0.8

o

F

1.2

o

F

SS Cool

1.2

o

F

1.7

o

F

HP Heat & Cool

1.2

o

F

1.7

o

F

Enter Menu

SYSTEM

Press
and hold
for 3 seconds

Set at

Home