Remove the Old Thermostat

1. Turn off power to the heating and cooling system.
2. Remove the front cover of the old thermostat, this usually

pulls off.

3. Loosen the screws that hold the thermostat to the wall.
4. Identify each wire attached to the old thermostat.
5. Disconnect the wires from old thermostat one at a time.

DO

NOT LET WIRES FALL BACK INTO THE WALL.

Install the New Thermostat

1. Open the battery door and detach the new thermostat

cover from the base.

2. With the base flush against the wall, mark mounting hole

locations on wall.

3. Move base out of the way and drill mounting holes.
4. Push wires through wire opening.
5. Position the base on the wall again and screw the mounting

screws into the wall anchors.

6. Connect each wire coming from the wall to its corresponding

terminal as shown in Fig. 2 thru 4 on page 7.

NOTE

Wires will not be connected to all terminals of the terminal
block.

Installation

Mounting

Hole

Mounting

Hole

Opening

for wires

Gas/Elec

Switch

Battery

Door

O/B

Switch

Figure 1. Thermostat Base

Set Switches

Gas / Elec Switch

If your system is a heat pump, the GAS/ELEC Switch must
be set to ELEC (see Fig. 1) If your system is a single stage,
the switch must be set to GAS. The switch setting must agree
with the system configuration selected in the configuration
menu.

O/B Terminal Switch Selection

The O/B switch on this thermostat is factory set to the “O”
position. This will accommodate the majority of heat pump
applications, which require the changeover relay to be
energized in COOL. If the thermostat you are replacing or the
heat pump being installed with this thermostat requires a “B”
terminal, to energize the changeover relay in HEAT, the O/B
switch must be moved to the “B” position.

Check Thermostat Operation

Heating System

1. Move SYSTEM switch to

HEAT position. If the heating

system has a standing pilot, be sure to light it.

2. Press

to adjust thermostat setting to 1° above room

temperature. The heating system should begin to operate.

3. Press

to adjust temperature setting below room

temperature. The heating system should stop operating.

Fan Operation

If your system

does not have a G terminal connection, skip to

Heating System.
1. Move SYSTEM switch to OFF position.

2. Move fan switch to

ON position. The blower should begin

to operate.

3. Move fan switch to

AUTO position. The blower should stop

immediately.

Cooling System

1. Move SYSTEM switch to

COOL position.

2. Press

to adjust thermostat setting below room

temperature. The blower should come on immediately on
high speed, followed by cold air circulation. However, if the
setpoint temperature is flashing, the compressor lockout
feature is operating (see Configuration menu, item 5).

3. Press

to adjust temperature setting above room

temperature. The cooling system should stop operating.

Wire Terminal Block

R

C

O/B

W

Y

G

Press down

Insert

Wire