Installation/ programming – Wayne-Dalton Z-WAVE HA14WD User Manual
Page 5
programming/operation
Refer to your specific controller’s user manual for detailed instructions on adding modules
(devices) to a Z-Wave® network. Refer to diagram below for control and programming functions
of switch.
Press and Release to turn light
oFF.
Press and Hold to adjust
DIM level
to desired level. (Release at desired
level.)
(Alternate) Press and Release to
InCLUDe/eXCLUDe to Network or
Scene.
Press and Release to
ADD into
Scene in
oFF position.
Press and Hold to
ADD into Scene
at desired
DIM level. (Release at
desired level.)
Press and Release to turn light
on.
Press and Hold to
DIM light up to
specific level. (Release at desired
level.)
Press and Release to
InCLUDe/
eXCLUDe to Network or Scene.
Press and Release to
ADD into
Scene in
on position.
Press and Hold to
ADD into Scene
at specific
DIM level. (Release at
desired level.)
LED ON indicates switch is ON.
LED flashing indicates switch is
communicating with Z-Wave
®
network.
Bottom of rocker switch:
A.
B.
C.
D.
e.
top of rocker switch:
A.
B.
C.
D.
e.
LeD:
A.
B.
Installation (continued)
Installation/
programming
5
10. Test switch by pressing the upper part of the rocker switch to turn the lights ON and pressing the lower
part of the rocker switch to turn the lights OFF. The lights should turn ON and OFF.
If lights do not turn on,
refer to the troUBLeSHootInG section.
11. Upon successful testing, finish mounting the HA14WD unit to the wall box with the screws provided and
install a decorator wall plate (not provided.)
troubleshooting
1. Light does not turn on:
• Lamp bulb is burned out - Replace.
• Air-Gap switch is in OFF position - Move slide switch to left.
• Wire connection is broken - Following all safety precautions, remove switch and check all connections.
• Circuit breaker or fuse has tripped - Reset/Replace.
2. Light flickers:
• Lamp bulb is not screwed in properly. - Check and tighten.
• Wire connection is intermittent - Following all safety precautions, remove switch and check connections.
3. Z-Wave® controller will not operate switch:
• Lamp bulb is burned out - Replace.
• Switch was programmed in the OFF position - Reprogram to ON position.
• Air-Gap switch is in OFF position - Move slide switch to left.
• Switch is not programmed to Network or Scene - Reprogram.