Lgb-6 to lgb-20, Csd-1 control system – propane gas, Propane gas – Weil-McLain LGB 6-20 Series User Manual

Page 6: Series 2 – control supplement, Water, Steam, Figure 3 wiring diagram, Schematic wiring diagram, Ladder wiring diagram, A united dominion company

background image

Part Number 550-141-816/0798

6

LGB-6 to LGB-20

Series 2 – Control Supplement

Part Number 550-141-816/0798

7

CSD-1 Control System – Propane gas

Figure 3

Wiring diagram

SENSOR

MAIN FLAME

FIRING RATE CONTROL

(WHEN USED)

STAGE COMBINATION

VALVE W/REGULATOR

MAIN GAS VALVE - TWO

MAIN GAS VALVE TERMINAL.

FIELD WIRED TO GAS VALVE OR FIRING

IGNITION CONTROL PANEL TERMINAL.

TRANSFORMER TERMINAL.

CONTROL MODULE TERMINAL.

FACTORY WIRED TO CONTROL -

24

120

DISCONNECT

A. U.S.A. - NATIONAL ELECTRICAL CODE AND ANY OTHER NATIONAL, STATE, OR LOCAL

3. IF ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, TYPE

ELECTRICAL SHOCK HAZARD, CAN CAUSE SEVERE INJURY OR DEATH.

A. U.S.A. - N.E.C. CLASS 1.

APPLICATION INFORMATION.

105 DEGREES C OR ITS EQUIVALENT MUST BE USED. EXCEPTION, SEE NOTE 6.

4. REFER TO CONTROL COMPONENT INSTRUCTIONS PACKED WITH BOILER FOR

DISCONNECT POWER BEFORE INSTALLING AND/OR SERVICING.

1. ALL WIRING MUST BE INSTALLED IN ACCORDANCE WITH:

B. CANADA - C.S.A. C22.1 CANADIAN ELECTRICAL CODE PART 1 AND ANY OTHER

2. ALL WIRING EXTERNAL TO BOILER JACKET MUST BE:

B. CANADA - C.S.A. C22.1 C.E.C. PART 1.

NOTES:

NATIONAL, PROVINCIAL, OR LOCAL CODE REQUIREMENTS.

CODE REQUIREMENTS.

TRANSFORMER

WIRE NUTS (2)

24

V.A.C.

120

W

V.A.C.

BK

C

R

N

EQUIPMENT

GROUND

(NOTE 9)

V.A.C.

WIRE NUTS (3)

W

V.A.C.

C

HIGH VOLTAGE FACTORY

10. ALL CONTACTS SHOWN WITHOUT POWER APPLIED - OFF SHELF CONDITION.

CONNECTED TO GAS VALVES AND FIRING RATE CONTROL TERMINALS (WHEN USED).

7. WIRES ARE FACTORY INSTALLED TO CONTROL PANEL, BUT MUST BE FIELD

6. REFER TO CONTROL SUPPLEMENT FOR GROUND LEADWIRE ATTACHMENT.

5. TERMINAL ON MAIN GAS VALVE IS A SINGLE TERMINAL (COMMON)

IF ORIGINAL GROUND LEADWIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED,

8. PILOT LEADWIRES ARE NOT FIELD REPLACEABLE. REPLACE PILOT ASSEMBLY IF NECESSARY.

9. DENOTES FIELD INSTALLED CHASSIS GROUND.

TYPE 125 C OR ITS EQUIVALENT MUST BE USED.

FOR LOW AND HIGH FIRE OPERATORS.

11. ALARM CONTACT RATINGS - 15 AMP @ 250 VAC.

MV/PV

IGNITION/SENSING CABLE

PANEL LAMP

RATE CONTROL.

NO. 2 BASE WIRING

(SIZES 13 THRU 20)

HIGH GAS

(WHEN USED)

SWITCH

PRESSURE

(NOTE 8)

PILOT

LOW VOLTAGE FIELD
HIGH VOLTAGE FIELD

LOW VOLTAGE FACTORY

WATER

LWCO

RESET

MANUAL

FROM TRANSFORMER

LIMIT CIRCUIT

TO LIMIT CIRCUIT

SERVICE SWITCH

(BY OTHERS)

H

FROM

FUSED

TRANSFORMER

BK

R

FROM TRANSFORMER

TEMPERATURE

OPERATING/LIMIT

CONTROL

COMBINATION

RESET

MANUAL

HIGH LIMIT

STEAM

LIMIT CIRCUIT

LOW WATER

BOX

JUNCTION

OPERATING

CONTROL

CUT-OFF

WIRE NUTS (4)

RESET

HIGH

LWCO

LIMIT

MANUAL

RESET

HIGH LIMIT

MANUAL

(NOTE 8)

(SIZES 6 THRU 20)

NO. 1 BASE WIRING

SOLENOID

SWITCH

(WHEN USED)

PRESSURE

HIGH GAS

NOTE 11

PILOT

MV

MV/PV

PV

R

NOTE 6

W

BL

NO.1 RED FLAME FAILURE LAMP

PILOT

SCHEMATIC WIRING DIAGRAM

PILOT PROVING MODULE

A United Dominion Company

Michigan City, IN 46360-2388

550-141-835/0798WM

PILOT PROVING MODULE

LGB

Propane Gas

NO. 2 BASE

PART NUMBER

Steam or Water

Intermittent Pilot

CSD-1 Control System

6 thru 20

Weil-McLain

500 Blaine St.

HIGH GAS

(WHEN USED)

SWITCH

PRESSURE

MAIN FLAME PROVING MODULE

NO. 2 BASE

R

OPERATOR (NOTE 5)

MAIN GAS VALVE HIGH FIRE

(NOTE 5)

MV/PV

SECONDARY GAS VALVE

PILOT SOLENOID VALVE

MAIN GAS VALVE LOW FIRE OPERATOR

(WHEN USED)

NOTE 11

ALARM

ALARM

24V

(WHEN USED)

SWITCH

PRESSURE

HIGH GAS

SENSE

NO. 1 BASE

SPARK

(GND)

24V

PV

1

N/A

SEE

NO. 1 BASE

PILOT FLAME SENSOR

MAIN FLAME PROVING MODULE

PILOT BURNER

(NOTE 8)

2

ALARM

ALARM

(GND)

SENSE

24V

24V

PV

MV/PV

MV

MAIN FLAME SENSOR

PV

MV

(STEAM ONLY)

LADDER WIRING DIAGRAM

LOW WATER

CUT-OFF

(BY OTHERS)

R

SERVICE SWITCH

R

OPERATING

CONTROL

H

FIRING RATE CONTROL

120 V.A.C.

MANUAL

LWCO

RESET

RESET

MANUAL

HIGH LIMIT

24 V.A.C.

PRIMARY

HIGH
LIMIT

PRIMARY

24 V.A.C.

MV/PV

GROUND

C

C

(NOTE 9)

EQUIPMENT

N

A

A

2

1

VALVE

R

N/A

SPARK

SENSE

(GND)

24V

PV

1

24V

ALARM

ALARM

SENSE

PV

NOTE 11

A

1

A

2

SEE

MV/PV

MV

PILOT SOLENOID VALVE

MV/PV

(NOTE 5)

MAIN GAS VALVE LOW FIRE OPERATOR

MAIN GAS VALVE HIGH FIRE

OPERATOR (NOTE 5)

MV/PV

PILOT FLAME SENSOR

PILOT BURNER

(NOTE 8)

MAIN FLAME SENSOR

2

(GND)

24V

ALARM

ALARM

24V

PV

FIRING RATE CONTROL

(WHEN USED)

MV

SOLENOID

VALVE

PILOT

NOTE 11

NOTE 6

R

VALVE W/REGULATOR

STAGE COMBINATION

MAIN GAS VALVE - TWO

MV

MV/PV

PV

BL

W

FIRING RATE CONTROL

(WHEN USED)

MAIN FLAME

SENSOR

NO.2 RED FLAME FAILURE LAMP

MV/PV

MV

MV/PV

MV

MOMENTARY

SWITCH

R

TERMINAL

BLOCK

24 V

IGNITION CONTROL

SPARK

SENSE

SPARK

24V (GND)

PILOT PROVING
MODULE

MV/PV

MV

ALARM

ALARM

PV

PRE-WIRED PANEL

1

2

A

1

A

2

IMPULSE

RELAY

IGNITION CONTROL

SENSE

24V (GND)

PROVING MODULE

MAIN FLAME

ALARM
24 V

ALARM

PV

MV/PV

MV

WIRE TIE

CLIP

MOMENTARY

SWITCH

R

TERMINAL

BLOCK

24 V

IGNITION CONTROL

SPARK

SENSE

SPARK

24V (GND)

PILOT PROVING
MODULE

MV/PV

MV

ALARM

ALARM

PV

PRE-WIRED PANEL

1

2

A

1

A

2

IMPULSE

RELAY

IGNITION CONTROL

SENSE

24V (GND)

PROVING MODULE

MAIN FLAME

ALARM
24 V

ALARM

PV

MV/PV

MV

WIRE TIE

CLIP

THERMOCOUPLE LEAD

BOX

SWITCH

PILOT

THERMOCOUPLE

THERMOCOUPLE

SWITCH

PILOT

BOX

PILOT

STANDING

SWITCH

PILOT

BOX

PILOT

STANDING

THERMOCOUPLE

SWITCH

PILOT

BOX

THERMOCOUPLE

MV/PV

PV

SECONDARY GAS VALVE

MV/PV

PV

BL

W

W

BL

MV/PV

MV

PV

SECONDARY

GAS VALVE

BK

BK

BL

W

W

BL

MV/PV

MV

PV

SECONDARY

GAS VALVE

BK

BK