HearthStone Quality Home Heating Products Inc ®

Model 8220

28

S

AFETY

L

ABEL

CONTACT YO UR LOCAL BUILDING

OFFICIALS ABOUT RESTRICTIONS

Listed Room Heater, Solid Fuel Type

Inte rtek Testing

Services NA, inc.

SERIAL #

MODEL NAME: DEVA 8220

TESTED TO: UL 1482, ULC S627

Do not use grate or elevate fire. Build
wood fire directly on hearth.

Do not operate with doors open.

WARNINGS:

“PREVENT HOUSE FIRES”

C learance to Comb ustible Materials*

Date of Manufacture

2007 2008 2009 Jan Feb Mar Apr M ay Jun Jul Aug Sep Oct Nov Dec

DO NOT REMOVE OR COVER THIS LABEL

3300-619 Rev A

U.S. ENVIRONMENTAL PROTECTION A GENCY

Certified to comply with July 1, 1990 particulate emissions standards

* Refer to the Installation Manual for addition al clearance information.

A - 10”(26 cm)
B - 10”(26 cm)

C - 16”(41cm)

6 inch diameter, single wall, minimum 24 MSG black or 25 MSG blue steel
connector with listed factory-built Type HT chimney or lined masonry chimney.

W N 04380

INSPECTION IN YOUR AREA

AND INSTALLATION

TYPE OF FUEL: Solid Wood Only

CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP

CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY
CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS.
INSPECT AND CLEAN CHIMNEY AND CONNECTOR

FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE,
CREOSOTE BUILDUP MAY OCCUR RAPIDLY.

VENT REQUIREMENTS:

When installed on a combustible floor, minimal hearth protection must be a non-
combustible material with an R-value of at least 0.89 underneath the cookstove that
extends 16”US (46cm CAN)

ear exit of the stove, the floor

protection must extend under the flue connector and extend 2” beyond each side of
the pipe.

beyond the fuel loading door and 8”US (20cm CAN)

beyond each side of the cookstove. If using the r

Do not obstruct space under heater

Do not over-fire. If the heater or chimney
connector glows, you are over-firing.

STOVE

BA CK WALL

SI

D

EW

AL

L

D

C

B

SI

D

EW

AL

L

Install and use only in accordance with
manufacture’s installation instructions
and your local building codes.

CAUTION: Special methods are required
when passing chimney through a wall or
ceiling, refer to local building codes. Do

not connect this unit to a chimney flue
serving another appliance.

NOTE: Replace fireb ox glass only with
4mm CERAMIC gla ss

M anufactured by:

Industrias Hergom S.A. for
Apdo. de Correos, 208 de Santander

Santander, Spain 390 80

USA

317 Stafford Ave.

Morrisville VT 05661

A

D - 2 1.5”(55cm)

Single w all connecto r

Alcove

A - 7” (18 cm)

B - 16” (41cm)
C - 16” (41cm)
D - 21.5” (55cm)