28 s, Afety, Abel – Weiman Products Deva 100 User Manual
Page 28
HearthStone Quality Home Heating Products Inc ®
Model 8220
28
S
AFETY
L
ABEL
CONTACT YO UR LOCAL BUILDING
OFFICIALS ABOUT RESTRICTIONS
Listed Room Heater, Solid Fuel Type
Inte rtek Testing
Services NA, inc.
SERIAL #
MODEL NAME: DEVA 8220
TESTED TO: UL 1482, ULC S627
Do not use grate or elevate fire. Build
wood fire directly on hearth.
Do not operate with doors open.
WARNINGS:
“PREVENT HOUSE FIRES”
C learance to Comb ustible Materials*
Date of Manufacture
2007 2008 2009 Jan Feb Mar Apr M ay Jun Jul Aug Sep Oct Nov Dec
DO NOT REMOVE OR COVER THIS LABEL
3300-619 Rev A
U.S. ENVIRONMENTAL PROTECTION A GENCY
Certified to comply with July 1, 1990 particulate emissions standards
* Refer to the Installation Manual for addition al clearance information.
A - 10”(26 cm)
B - 10”(26 cm)
C - 16”(41cm)
6 inch diameter, single wall, minimum 24 MSG black or 25 MSG blue steel
connector with listed factory-built Type HT chimney or lined masonry chimney.
W N 04380
INSPECTION IN YOUR AREA
AND INSTALLATION
TYPE OF FUEL: Solid Wood Only
CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP
CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY
CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS.
INSPECT AND CLEAN CHIMNEY AND CONNECTOR
FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE,
CREOSOTE BUILDUP MAY OCCUR RAPIDLY.
VENT REQUIREMENTS:
When installed on a combustible floor, minimal hearth protection must be a non-
combustible material with an R-value of at least 0.89 underneath the cookstove that
extends 16”US (46cm CAN)
ear exit of the stove, the floor
protection must extend under the flue connector and extend 2” beyond each side of
the pipe.
beyond the fuel loading door and 8”US (20cm CAN)
beyond each side of the cookstove. If using the r
Do not obstruct space under heater
Do not over-fire. If the heater or chimney
connector glows, you are over-firing.
STOVE
BA CK WALL
SI
D
EW
AL
L
D
C
B
SI
D
EW
AL
L
Install and use only in accordance with
manufacture’s installation instructions
and your local building codes.
CAUTION: Special methods are required
when passing chimney through a wall or
ceiling, refer to local building codes. Do
not connect this unit to a chimney flue
serving another appliance.
NOTE: Replace fireb ox glass only with
4mm CERAMIC gla ss
M anufactured by:
Industrias Hergom S.A. for
Apdo. de Correos, 208 de Santander
Santander, Spain 390 80
USA
317 Stafford Ave.
Morrisville VT 05661
A
D - 2 1.5”(55cm)
Single w all connecto r
Alcove
A - 7” (18 cm)
B - 16” (41cm)
C - 16” (41cm)
D - 21.5” (55cm)
Hearth Prot ection