Specifications

WD Enterprise WDE2170/WDE4360

RELEASED 04-08-97

4079-001045 Rev. B

16

2.5.2. Temperature and Humidity

Table 2-11. Temperature and Humidity

Temperature and Humidity

Operating

1

Temperature

Humidity

Thermal Gradient

5°C to 55°C (41°F to 131°F)

10-90% RH non-condensing

33°C (maximum wet bulb)

10°C/hour (maximum)

Non-Operating

Temperature

Humidity

Thermal Gradient

-40°C to 60°C (-40°F to 140°F)

5-95% RH non-condensing

33°C (maximum wet bulb)

20°C/hour (maximum)

1

The system environment must provide sufficient air flow to limit maximum

surface temperatures as defined in Table 2-12.

2.5.3. Cooling

Drive component temperatures must remain within the limits specified in Table 2-12.
Figure 2-7 and Figure 2-8 show the temperature measurement locations. Sustained
operation at temperatures in excess of the reliability values degrades the MTBF rating.
Short excursions up to, but not exceeding, the maximum values do not affect the MTBF
rating. Maximum component temperature ratings must not be exceeded under any
operating condition. The drive may require forced air cooling to meet specified
operating temperatures.

Table 2-12. Maximum & Reliability Operating Temperature Limits

Component

Location

Maximum

Reliability

1

Drive Baseplate

#1, Figure 2-7.

65

°

C (149

°

F)

55

°

C (131

°

F)

4915

#2, Figure 2-8.

95

°

C (203

°

F)

80

°

C (176

°

F)

64C96

#3, Figure 2-8.

80

°

C (176

°

F)

65

°

C (149

°

F)

2298

#4, Figure 2-8.

80

°

C (176

°

F)

65

°

C (149

°

F)

1501

#5, Figure 2-8.

85

°

C (185

°

F)

70

°

C (158

°

F)

1

Sustained operation at temperatures in excess of the reliability values degrades the MTBF

rating.