Mounting the Table
1. Mount the trunnion support bracket (A, Fig. 5)
to the bandsaw with four 5/16” x 1-1/2” hex cap 
bolts, and four 5/16” lock washers (B, Fig. 5). 
2. Remove the round table insert (C, Fig. 5) found
where the blade goes through the table. Also, 
remove the table pin (D, Fig. 5) found on the 
side of the table. 
3. Slide saw blade through slot in table where the
table pin was located. Rotate the table 90 
degrees so that the miter slot is parallel to the 
blade, and to the right of the blade when facing 
the bandsaw. 
4. Line up the trunnions so that the bolts feed
through the trunnion support bracket. Secure 
the table with two lock knobs (C, Fig. 6). 
Reinstall the table insert and table pin. 
5. Place a square (E, Fig. 5) on the table and
against the back edge of the blade. If the table 
needs adjusted, on the low side, loosen two 
bolts (B, Fig. 5) and turn the setscrew (F, Fig. 
5) until the table is approximately square to the 
back edge of the blade. 
Adjusting 90 Degree Table Stop
1. Blade tension and tracking must be properly
adjusted prior to table stop setup.
2. Loosen lock knobs (C, Fig. 6) and tilt table until
it rests against table stop bolt (D, Fig. 6). 
Tighten knobs. 
3. Use a square (G, Fig. 7) placed on the table
and against the blade to see if the table is 90 
degrees to the blade. 
4. If an adjustment is necessary, loosen the lock
knobs. Tilt the table until it is square to the 
blade, and tighten the lock knobs. 
5. Loosen lock nut (E, Fig. 6) and turn table stop
bolt (D, Fig. 6) until it contacts the table. 
Tighten the nut (E, Fig. 6) to hold table stop in 
place. When tightening the nut hold the table 
stop bolt in place with a wrench to prevent 
movement. 
6. If necessary, adjust pointer (F, Fig. 6) to zero.
Figure 5
 
 
 
Figure 6
 
 
 
Figure 7
 
 
 
 
 