Mounting the Table

1. Mount the trunnion support bracket (A, Fig. 5)

to the bandsaw with four 5/16” x 1-1/2” hex cap
bolts, and four 5/16” lock washers (B, Fig. 5).

2. Remove the round table insert (C, Fig. 5) found

where the blade goes through the table. Also,
remove the table pin (D, Fig. 5) found on the
side of the table.

3. Slide saw blade through slot in table where the

table pin was located. Rotate the table 90
degrees so that the miter slot is parallel to the
blade, and to the right of the blade when facing
the bandsaw.

4. Line up the trunnions so that the bolts feed

through the trunnion support bracket. Secure
the table with two lock knobs (C, Fig. 6).
Reinstall the table insert and table pin.

5. Place a square (E, Fig. 5) on the table and

against the back edge of the blade. If the table
needs adjusted, on the low side, loosen two
bolts (B, Fig. 5) and turn the setscrew (F, Fig.
5) until the table is approximately square to the
back edge of the blade.

Adjusting 90 Degree Table Stop

1. Blade tension and tracking must be properly

adjusted prior to table stop setup.

2. Loosen lock knobs (C, Fig. 6) and tilt table until

it rests against table stop bolt (D, Fig. 6).
Tighten knobs.

3. Use a square (G, Fig. 7) placed on the table

and against the blade to see if the table is 90
degrees to the blade.

4. If an adjustment is necessary, loosen the lock

knobs. Tilt the table until it is square to the
blade, and tighten the lock knobs.

5. Loosen lock nut (E, Fig. 6) and turn table stop

bolt (D, Fig. 6) until it contacts the table.
Tighten the nut (E, Fig. 6) to hold table stop in
place. When tightening the nut hold the table
stop bolt in place with a wrench to prevent
movement.

6. If necessary, adjust pointer (F, Fig. 6) to zero.

Figure 5



Figure 6



Figure 7