TROUBLE SHOOTING CONTINUED:

In this coffee brewer there are two elements in parallel. Failure of either will cause very

slow heating. Perform the following tests:

a. Clamp-on ammeter test: If both elements are good, you will measure about 21

amps at 240 volts or 24 amps at 208 volts. Use heavy wire from the contactor to

measure the current. If you measure only 10 to 12 amps, check the current to each

element to identify defective unit.

b. Ohmmeter or continuity test: Disconnect all power by unplugging unit, or de-en

ergizing circuit breaker (switch on back of unit does not disconnect L2). Disconnect

one terminal to measure each element. They should each have continuity or mea-

sure about 20 ohms.

4. Burned out heating element

SOLUTION

POSSIBLE CAUSE

PROBLEM: WATER IN TANK DOES NOT REACH PROPER TEMPERATURE

SOLUTION

POSSIBLE CAUSE

PROBLEM: WATER BOILING, HEATING ELEMENTS DO NOT SHUT OFF.

1. Defective thermostat

If ready to brew light does not come on, replace thermostat. You can sometimes operate

temporarily by turning the thermostat shaft counterclockwise until brew light comes on

and boiling stops.

SOLUTION

POSSIBLE CAUSE

1. Water level is too low in heating

tank.

2. Defective brew switch

3. Defective brew valve

4. Clogged fittings or tubing

Check water level in tank (it should be filled up to the probe tip). If water does not flow

into tank, review steps 1 thru 4, previous page.

Check the continuity between terminal 4B & 5B. When the switch is pressed, there

should be solid continuity between these two terminals. If not, replace the switch.

Push the brew switch to start the timer. The light on this switch will indicate that the timer

is on and it will energize the coil of the dump valve to open it. You should read 110/120V

at the coil terminals. If this voltage is present but the valve does not open, the coil is

burned out. Replace the coil or the valve.

Check for lime buildup in the tank outlet fitting, sprayhead fitting, or the sprayhead. Clean

as necessary. Also check for kinks or blockage in the flexible tubing.

PROBLEM: WATER NOT FLOWING FROM SPRAYHEAD.

C1000AP & C1000APT Airpot Brewer

If READY TO BREW light comes on, but water keeps boiling, contactor is stuck. Replace

it. Under this condition, no voltage should be present at the contactor coil.

2. Defective contactor