CARE AND MAINTENANCE OF C1000 AP

Preventive maintenance is essential in keeping your Curtis coffee brewer performing at it's peak. Regular

cleaning will pay off with an appealing, high performance, coffee brewing machine.

Preventive Maintenance

1. Remove the sprayhead from brewer and clean it once a week; more often in heavy lime areas.

2. The inside of the heating tank may, occasionally, require removing of lime build-up. The frequency

is determined by local water conditions.

Cleaning

Using a daily routine of cleaning, the external parts of the C1000 AP should maintain it's new appearance

and ensure that the flavor of the coffee is always good.

1. Wipe off any spills, dust or debris that may fall on exterior surfaces.

2. Slide out the brew cone and rinse.

3. Clean sprayhead and dome around the sprayhead. Use a non-toxic cleaner.

4. Clean the brew cone slide rails with a brush or damp cloth. Dry thoroughly.

Stainless Steel Polish can be used to clean the outside surfaces of the C1000 AP coffee brewer. This is to

prevent scratching of the stainless steel surfaces.

CAUTION - Do not use cleansers, bleach liquids, powders or any other substance containing

chlorine. These products will promote corrosion and will pit the stainless steel. USE OF THESE

PRODUCTS WILL VOID YOUR WARRANTY.

POSSIBLE CAUSE

SOLUTION

PROBLEM: WATER DOES NOT FLOW INTO HEATING TANK.

1. Water line turned off or

water filter needs changing

2. Water inlet valve coil burned out

TROUBLESHOOTING

These procedures apply specifically to model C1000AP-10 and C1000APT-10. They also apply to airpot

brewers with other dash numbers which are based on the -10 schematic, primary units rated 220 volts,

5100 watts, three wire plus ground. If the serial nameplate electrical rating differs, some measured volt-

ages, currents, and resistances will be different than shown on the standard -10 schematic.

Open the line and make sure you are getting enough water to brewer.

Turn machine off. Disconnect wires from water inlet coil terminals and connect a

power cord to the terminals. Plug cord into a 120V outlet and verify if water flows

when plugged in and stops when power is disconnected. If valve fails this test,

replace valve.