beautypg.com

White Rodgers 90 User Manual

Page 17

background image

15

contact the manufacturer of your
heating/cooling equipment.

System and Thermostat Diag-
nostics.

The display will indicate

CHECK

SYS

if the room temperature does not

rise within two hours of the call for
heat. After two hours the thermostat
will quit calling for heat for one
minute (this allows some furnaces to
reset) and call for heat again. It will
repeat this sequence three times. If the
temperature still does not rise, it will
continue to call for heat. This normally
indicates the heating system is not
working correctly. You may wish to
consult your furnace manufacturer or
service person.

The display will indicate

CHECK

STAT

if one of the following occurs.

• One of the keys is stuck down or in.
Check the keys, make sure nothing is
pushing them in.

The following steps will allow you to
change the number of hours for filter
change-out.

1. If

CHNG FLTR

is on the display,

press the FILTER key once to reset
the timer. If you do not see

CHNG

FLTR

proceed to step 2.

2. Press the FILTER key, The display
will show

SET FILTER TIME

and the

number of hours remaining before

CHNG FLTR indicator will display.

3. Press the FILTER key a second
time. The display will show

SET

FILTER TIME

and will show the

number of hours to filter change.

4. Press TIME

FWD

or TIME

BACK

to change the time to your require-
ments.

5. Press PROGRAM

RUN

to return

to the normal operating mode.

NOTE: If unsure what interval to use
between filter changes or cleaning,

• The thermostat sensor is not
functioning. If using a remote sensor,
check connections, wiring and power.

After checking the above, press
PROGRAM

RUN

to reset the

display. If this does not clear the
display, disconnect power for five
minutes.

If these checks fail to solve the
problem, the thermostat should be
replaced.

Temporary Program Override.

Any time your program is running and
you would like to override it for a
specific amount of time, press
or

until the temperature you

want is displayed. The display will
indicate

HOLD

, and the number of

hours remaining in the hold period will
be indicated with the word

HRS

. To

adjust the length of time for the
override, press TIME

FWD

or TIME

BACK

.

HOLD TILL

will be displayed

Features