PART I – GENERAL

1.01 Section Includes

A. Sectional overhead doors [manually] [motor]

operated with accessories and components.

1.02 Related Work

A. Opening preparation,miscellaneous or structural

steel work,access panels finish or field painting are in

the scope of work of other trades and divisions of

these specifications.

1.03 Reference Standards

A. ANSI/DASMA 102 –American National

Standards Institute [A216.1] Specifications for

sectional overhead doors published by Door &

Access Systems ManufacturersAssociation

International in bulletin 102-1990.

B. ASTM A123 – Zinc [hot-dipped galvanized]

coatings on iron and steel products.

C. ASTM A216 – Specifications for sectional

overhead type doors.

D. ASTM A229 – Steel wire,oil-tempered for

mechanical springs.

E. ASTM A-653-94 – Steel sheet,zinc-coated

[galvanized] by the hot-dipped process,

commercial quality.

F. ASTM E330 – Structural performance of

exterior windows,curtain walls,and doors by

uniform static air pressure difference.

G. ASTM E413-87 – Sound transmission class.

Acoustical performance value = 24 per.J.

H. ASTM E1332-90 – Outdoor-indoor

transmission class. Acoustical performance value = 20.

1.04 Quality Assurance

A. Sectional overhead doors and all accessories and

components required for complete and secure

installations shall be manufactured as a system from

one manufacturer.

1.05 Systems Description

A. Sectional Overhead Door:Type:

Model 2411

B. Mounting:Continuous angle mounting for [steel]

[wood] jambs [bracket mounting for wood jambs]

C. Operation:[manual push-up] [chain hoist] [motor]

[motor with chain hoist]

D. Material:Galvanized steel with polyester finish paint

E. Insulation:Optional [polystyrene] [polyurethane]

1.06 Submittals

A. Shop Drawings:Clearly indicate the following:

1. Design and installation details to withstand

standard windload.

2. All details required for complete operation

and installation.

3. Hardware locations.

4. Type of metal and finish for door sections.

5. Finish for miscellaneous components and

accessories.

B. Product Data:Indicating manufacturer’s product

data,and installation instructions.

1.07 Delivery, Handling, Storage

A. Deliver products in manufacturer’s original

containers,dry,undamaged,seals and labels intact.

B. Store and protect products in accordance with

manufacturer’s recommendations.

1.08 Warranty

A. Standard manufacturer’sTENYEAR warranty against

cracking,splitting or deterioration due to rust-through.

PART I I – PRODUCTS

2.01 Manufacturer

A. Wayne-Dalton or approved equal Model 2411

insulated sectional overhead doors of steel

construction complete as specified in this section and

as manufactured by Wayne-Dalton Corp.,

Mt.Hope,Ohio.

2.02 Materials

A. Door Sections:Shall be of roll formed steel type with

“c” shaped 20 ga.[intermediate and end stiles

construction] and calculated materials“R”- value of

7.64 [optional] in accordance with industry guidelines.

1. Exterior Skin:Structural quality,hot-dipped

galvanized steel, with embossed stucco finish

nominal 24 ga.with baked-on polyester primer and

[white] [brown] polyester finish coats with

non-repeating random stucco texture and

2 deep and 4 shallow pinstripes.

2. Insulation:Cavity shall be filled with laid-in-place

[polyurethane] [expanded polystyrene] and

covered with [vinyl] [ 0.022” minimum embossed

steel] held in place with polymer clips.

B. Track:Track design shall be [standard lift] [high lift]

[vertical lift] [low headroom].Vertical mounting angles

shall be hot-dipped galvanized.Track size shall be [2"]

[3"].Vertical track shall be graduated to provide wedge

type weathertight closing with continuous angle

mounting for [steel] [wood] jambs,and shall be fully

adjustable to seal door at jambs [bracket mount for

wood].Horizontal track shall be reinforced with

continuous angle of adequate length and gauge to

minimize deflection.

Note: Horizontal track applies to standard lift,high lift,low

headroom and follow-the-roof designs only.

C. Hardware:Hinge and RollerAssembly:

1. Hinges and brackets shall be made from hot-

dipped,galvanized steel.

2. Track rollers shall be case-hardened inner

steel races with 10-ball [2"] [3"] rollers.

3. All factory authorized attachments shall be

made at locations indicated.

D. Counterbalance:

1. Springs shall be torsion type,low-stress,helical

wound,oil-tempered spring wire to provide

minimum [10,000 standard] [25,000] [50,000]

[100,000] cycles of use,on continuous steel [solid].

2. Spring fittings and drums made of die cast,high

strength aluminum.

3. Pre-formed galvanized steel aircraft cable shall

provide a minimum of a 5:1 safety factor.

2.03 Operation

A. Operation shall be [manual push-up] [chain

hoist] [motor] [motor with chain hoist].

Note: Manufacturer does not recommend chain

hoists or jack shaft operators on the following

track applications.

• 15" radius standard lift with roof pitch

less than 2:12

• Hi-lift less than 24"

• Hi-lift between 12" – 23" with roof pitch

less than 1:12

• Low headroom track

Special chain hoist assemblies (using a trolley rail)

are available for the above track systems.

2.04 Locks

A. Locks shall engage the right-hand vertical track and

utilize [an interior side lock] [standard size rim

cylinder].

2.05 Weatherstripping

A. Doors shall be equipped with vinyl bulb shaped astragal

as standard on the bottom section.Optional joint,top.

head and jamb seal are available.

2.06 Glazing

A. Optional.

2.07 Windload

A. Windload – per DASMA 102-2003 and as required by

local codes.

PART III – EXECUTION

3.01 Installation

A. General:

1. Install doors in accordance with manufacturer’s

instructions and standards.Installation shall be by an

authorizedWayne-Dalton representative.

2. Verify that existing conditions are ready to receive

sectional overhead door work.

3. Beginning of sectional overhead door work means

acceptance of existing conditions.

B. Install door complete with necessary hardware,jamb

and head mold strips,anchors,inserts,hangers,and

equipment supports in accordance with final shop

drawings,manufacturer’s instructions,and as specified

herein.

C. Fit,align and adjust sectional overhead door assemblies

level and plumb for smooth operation.

D. Upon completion of final installation,lubricate,test and

adjust doors to operate easily,free from warp,twist or

distortion and fitting for entire perimeter.

Note: Architect may consider providing a schedule when

more than one sectional overhead door or opening

type is required.

3.02 Materials (See note above.)