beautypg.com

Wayne 352205-001 User Manual

Page 6

background image

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

Pump won’t run

Motor hums but
pump won’t run

Pump runs but
pumps very little
or no water

Pump cycles too
frequently

6

Operating Instructions and Parts Manual

www.waynepumps.com

1. Check all connections
2. Check battery and replace if low or defective
3. Make sure nothing is interfering with operation of switch

4. Check internal fuse located inside the control box. Pull the

charger from the wall outlet and remove. If the fuse is blown,
replace it with a 20 amp automotive type fuse

1. Check battery and replace if low or defective
2. Unplug pump, remove screen, and check to see if impeller is free

to turn. If impeller is locked, remove the 7 screws on the bottom
of the pump to release the housing around the impeller. Remove
the obstruction. Reassemble pump and reconnect

1. Check to make sure check valves installed between primary

pump discharge and Backup Sump Pump are functioning
properly

2. Check for obstruction and clear if necessary
3. If discharge is too high, a separate line may be required with a

lower discharge height

4. Check battery and replace if low or defective

1. Check to make sure check valves installed between primary

pump discharge and Backup Sump Pump are functioning
properly

1. Connections not secure
2. Low or defective battery
3. Float switch stuck

4. Defective or blown fuse

1. Defective battery
2. Impeller is locked

1. Check valve missing or improperly

installed

2. Obstruction in discharge pipe
3. Discharge pipe length and/or

height exceeds capacity of pump

4. Low or defective battery

1. Check valve problem