beautypg.com

Wayne PC2 Series User Manual

Page 4

background image

Operating .Instructions .and .Parts .Manual

Troubleshooting Chart

www.waynepumps.com

Symptom

Possible Cause(s)

Corrective action

Pump .will .not .start .or .run

1 . .Blown .fuse

1 . .If .blown, .replace .with .proper .sized .fuse .or .

reset .breaker

2 . .Low .line .voltage

2 . .Voltage .of .power .supply .must .match .the .

voltage .of .the .pump

3 . .Worn .brushes

3 . .Replace .brushes

4 . .Impeller .blocked

4 . .Remove .blockage

5 . .Motor .has .overheated . .(Model .PC2 .only)

5 . .Disconnect .from .power .supply .and .allow .to .

cool .(Minimum .10 .minutes)

Pump .will .not .prime .or .
retain .prime .after .operating

1 . .Air .leak .in .suction .line

1 . .Repair .suction .line .by .tightening .inlet .

connection .or .replace

2 . .Impeller .blocked

2 . .Remove .blockage

3 . .Worn .seal

3 . .Replace .seal

4 . .Suction .lift .too .high

4 . .Lower .pump

5 . .Hose .kinked .or .looped

5 . .Straighten .hose

6 . .Fittings .not .tight

6 . .Tighten .fittings

7 . .Suction .hose .out .of .water

7 . .Submerge .suction .hose .end

8 . .Clogged .inlet

8 . .Clean .inlet

Flow .rate .is .too .low

1 . .Inlet .hose .plugged .or . . .

. . . . . . .

kinked

1 . .Clean .or .replace

2 . .Low .line .voltage

2 . .Voltage .of .power .supply .must .match .the .

voltage .of .the .pump

Shaft .seal .leaks

1 . .Worn .seal

1 . .Replace .seal

2 . .Shaft .grooved

2 . .Replace .pump

3 . .Pump .head .loose .on .motor

3 . .Insure .proper .assembly .and .no .obstruction, .

tighten .bolts