Start Setup
End Setup
,ZZ, ,ZZ,
Case Conversion Settings:
Case
Conversion
no case conversion (AbCd -> AbCd)
default
,YZ,
convert to upper case (AbCd -> ABCD)
,YW,
convert to lower case (AbCd -> abcd)
,YX,
exchange case (AbCd -> aBcD)
,YY,
Output Format Settings:
The following additional characters can be included in each code that is scanned:
1) Preamble / Postamble (up to 8 digits)
Specified strings can be added in front and at the end of the data for all codes.
2) Prefix / Suffix (up to 4 digits)
Specified strings can be added in front and at the end of the data for a specific symbology.
By default, the prefix is empty and the suffix is a CR character.
3) Code Identification / Code Length
Code Identification and Code Length can be included in a prefix and/or a suffix.
Output Format:
Preamble
(max 8 digits)
Prefix for each code
(max 4 digits)
Data
Suffix for each code
(max 4 digits)
Postamble
(max 8 digits)
Preamble and
Postamble
preamble command
,MZ,
postamble command
,PS,
Preamble / Postamble Example Programming Sequence:
1) Scan “Start Setup”
2) Scan “Preamble Command” or “Postamble Command”
3) Scan up to 8 ASCII values from the ASCII Value Table
4) Scan “End Setup”
A-37