OPERATION

CHECK THERMOSTAT OPERATION

If at any time during testing your system does not operate

properly, contact a qualified service person.
Turn on power to the system.

Fan Operation

If your system does not have a G terminal connection, skip to

Heating System

.

1. Move fan switch to ON position. The blower should begin

to operate.

2. Move fan switch to AUTO position. The blower should stop

immediately.

Heating System

1. Move SYSTEM switch to HEAT position. If the auxiliary

heating system has a standing pilot, be sure to light it.

2. Press

to adjust thermostat setting to 1° above room

temperature. The heating system should begin to operate.

3. Press

to adjust temperature setting below room

temperature. The heating system should stop operating.

To prevent compressor and/or property damage, if the
outdoor temperature is below 50

o

F, DO NOT operate

the cooling system.

CAUTION

!

Do not allow the compressor to run unless the
compressor oil heaters have been operational for 6
hours and the system has not been operational for at
least 5 minutes.

CAUTION

!

Cooling System

1. Move SYSTEM switch to COOL position.
2. Press

to adjust thermostat setting below room

temperature. The blower should come on immediately on

high speed, followed by cold air circulation. However, if the

setpoint temperature is flashing, the compressor lockout

feature is operating (see Configuration menu, item 5).

3. Press

to adjust temperature setting above room

temperature. The cooling system should stop operating.