Unobstructed Airflow

Unobstructed airflow to and from the

unit is a critical factor in the unit’s overall

performance. Make sure there is a 3 ft.

horizontal clearance in the front of the

unit. This will assure that the unit can

move the air around in an efficient man-

ner. Avoid any attempt to camouflage

the unit by installing racking in front of

the unit. This will restrict the airflow and

lower the performance of the unit.

Mounting the Unit

The unit should be mounted within 18“ of the

top of the room in order to achieve sufficient

cooling. As the room cools down, the warm

air will rise to the ceiling. Mounting the Whis-

perKOOL high in the room will create a consis-

tently cool environment by capturing the warm

air and replacing it with cool air. Mounting the

unit low in the room will result in a temperature

variation in the room due to the unit’s inability

to draw warm air from the ceiling of the cellar to

the unit itself.

Door and Door Seal

An exterior grade (1 3/4”) door must be installed as a

cellar door. It is very important that weather stripping

is attached to all 4 sides of the door jam. A bottom

“sweep” or threshold is also required. The door must

have a very good seal to keep the cool cellar air from

escaping out of the cellar. One of the most common

problems with cooling units running continually is the

door not sealing properly. In cases where glass doors

are used and the room size is close to the recom-

mended unit size, the next larger size WhisperKOOL

should be used. This will compensate for the insula-

tion loss due to the inefficient door.

TM

Intake

Exhaust

Front of Unit

Exhaust Room

Wine Cellar