beautypg.com

Maintenance – Whirlpool WHER25 User Manual

Page 21

background image

21

Maintenance

FIG. 27

FLOW CONTROL

The flow control is vital for proper operation of the
Reverse Osmosis membrane cartridge. See Fig. 27. The
flow control, located in the red tube at the system hous-
ing, keeps water flowing through the membrane at the
required rate. This is to ensure the system produces the
best quality product water.

Periodically check the flow control assembly to be sure
the small hole through it is clean and unrestricted.

If the flow control assembly requires service, review the
exploded view in Fig. 27. Assemble and disassemble as
shown.

Flow
Control
Insert

1/4'' Red
Tubing

To

Drain

FIG. 29

FIG. 28

Collet

Push o-ring seal into
bottom of port then follow
with collet.

Fitting

O-Ring Seal

Change Collet and O-ring

Collet (Depress to
Remove Tubing)

Tubing

Disconnect Tubing

CHANGE COLLET AND O-RING

1. Remove the collet and o-ring from the fitting with a

small screwdriver. Be careful not to scratch the inter-
nal walls of the collet port. See Fig. 28-29.

2. Clean collet port, lubricate and insert the o-ring seal

into the bottom of the port. See Fig. 28-29.

3. Push the collet inward until it locks in place.See Fig.

28-29.

CHANGE BATTERY

To change battery, complete the following steps.
1. Loosen the screw on the right side of the faucet base.

See Fig. 30.

2. Press the battery housing upwards from the front faucet

base until it releases from the faucet base. See Fig. 30.

3. Replace the battery (Maxell-CR 2032 or equivalent).

Place battery into the holder with the positive (+) side
facing the back of the holder.

4. When the battery is first replaced it will flash six times

and turn off. This indicates the battery is fully charged.
After the six flashes the timer enters the 6 month time
cycle. If it repeatedly flashes two times, it is not a fully
charged battery.

5. Re-install the battery housing and firmly tighten the

mounting screw. See Fig. 30.