beautypg.com

Refrigeration, Installation requirements, Built-in 30”w. all freezer – Viking DFFB User Manual

Page 7: Electric outlet location water line entry area, Access requirements – dual installation

background image

REFRIGERATION

Built-In 30”W. All Freezer

P L A N N I N G A N D D E S I G N G U I D E

V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1

R E L E A S E D 1 2 / 1 / 0 7

© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE

9”

(22.9 c

m)

73-3/8”

(186.4

cm)

82-7/8”

(210.5 c

m) min.

anti-tip boar

d &

opening height

84-1/16”

(213.5 cm) ma

x.

anti-tip boar

d &

opening height

65-1/2”

Profession

al

(166.4 c

m)

66” Desi

gne

r/Cus

tom Fr

ont

(167

.6 cm)

24”*

(61.0 cm)

6-3/4”

(17.1 cm)

7-5/8”

(19.4

cm)

3”

(7.6 c

m)

5/8”

(1.5 c

m)

5/8”

(1.5 cm

)

10-1/

2”

(26.7 cm)

5/8”

(1.5 cm)

10-3/4”

(27.3 cm)

3-5/8”

(9.2 cm

)

Opt

iona

l floor

water line ent

ry

1”

(2.5

cm

)

See anti-tip boar

d installation

6”

(15.2 cm)

9”

(22.9 cm)

9”

(22.9 c

m)

73-3/8”

(186.4 cm)

82-7/8”

(210.5 cm)

min.

anti-t

ip boar

d &

opening height

84-1/16”

(213.5 cm) max.

anti-tip boar

d &

opening height

59-1/2”

Profession

al

(151.1

cm)

60” Des

igner/

Cust

om Fr

ont

(152

.4 cm)

24”*

(61.0 cm)

6-3/4”

(17.1

cm)

7-5/8”

(19.4 cm)

3”

(7.6 cm)

5/8”

(1.5 cm)

5/8”

(1.5 cm)

10-1

/2”

(26.7 c

m)

5/8”

(1.5 cm)

10-3/4”

(27.3

cm)

3-5/8”

(9.2 cm

)

Op

tional

floor

water

line

entry

1”

(2.5

cm

)

See anti-tip boar

d installation

6”

(15.2 cm)

9”

(22.9 cm)

Installation Requirements

VCFB304/VCRB364

DDFB304/DDRB364

DFFB304/DFRB364

Cutout width

65-1/2” (166.4 cm)

66” (167.6 cm)

66” (167.6 cm)

Cutout height

82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max.

Cutout depth

24” (61.0 cm) min.*

VCFB304/VCRB304

DDFB304/DDRB304

DFFB304/DFRB304

Cutout width

59-1/2” (151.1 cm)

60” (152.4 cm)

60” (152.4 cm)

Cutout height

82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max.

Cutout depth

24” (61.0 cm) min.*

30”/30” FREEZER/
REFRIGERATOR COMBINATION

30”/36” FREEZER/
REFRIGERATOR COMBINATION

ELECTRIC OUTLET LOCATION

WATER LINE ENTRY AREA

Note: cutout opening shown with All Freezer model on left.

Reverse water line entry if All Freezer model is on right

ELECTRIC OUTLET LOCATION

WATER LINE ENTRY AREA

Note: cutout opening shown with All Freezer model on left.

Reverse water line entry if All Freezer model is on right

ACCESS REQUIREMENTS – Dual Installation

*Custom front models fit flush in 25”-deep (63.5 cm) cabinet openings. They can be installed in standard 24”-deep openings. The

door faces and top grille will protrude 3/4” (1.9 cm) into the room.

This manual is related to the following products: