beautypg.com

Vmh10tnb, Vent-free natural gas compact fireplace, Installation – Vanguard Heating VMH10TNB User Manual

Page 14: Continued

background image

14

107031

VENT-FREE NATURAL GAS COMPACT FIREPLACE

VMH10TNB

®

CONNECTING TO GAS
SUPPLY

WARNING: A qualified ser-

vice person must connect fire-
place to gas supply. Follow all
local codes.

IMPORTANT:

Check gas line pressure be-

fore connecting fireplace to gas line. Gas
line pressure must be no greater than 14
inches of water. If gas line pressure is higher,
fireplace regulator damage could occur.

Installation must include an equipment
shutoff valve, union, and plugged 1/8" NPT
tap. Locate NPT tap within reach for test
gauge hook up. NPT tap must be upstream
from heater (see Figure 23).

IMPORTANT:

Install an equipment shutoff

valve in an accessible location. The equip-
ment shutoff valve is for turning on or shut-
ting off the gas to the appliance.

We recommend that you install a sediment
trap in supply line as shown in Figure 23.
Locate sediment trap where it is within
reach for cleaning. Install in piping system
between fuel supply and heater. Locate sedi-
ment trap where trapped matter is not likely
to freeze. A sediment trap traps moisture
and contaminants. This keeps them from
going into fireplace controls. If sediment
trap is not installed or is installed wrong,
fireplace may not run properly.

WARNING: Never connect

fireplace to private (non-utility)
gas wells. This gas is commonly
known as wellhead gas.

CAUTION: Use only new,

black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
1/2" or greater diameter to al-
low proper gas volume to fire-
place. If pipe is too small, un-
due loss of pressure will occur.

CAUTION: Use pipe joint seal-

ant that is resistant to liquid pe-
troleum (LP) gas.

Attaching Wood Base to Solid
Floor

For attaching base to solid floors (concrete
or masonry)

Note:

Floor anchors and mounting screws

are in hardware package. The hardware
package is provided with fireplace.

1.

Drill holes at marked locations using
5/16" drill bit. For solid floors (concrete
or masonry), drill at least 1" deep.

2.

Fold floor anchor as shown in Figure 22.

3.

Insert floor anchor (wings first) into
hole. Tap anchor flush to floor.

4.

Insert mounting screws through base
and into floor anchors.

5.

Tighten screws until base is firmly fas-
tened to floor.

Figure 22 - Folding Anchor

INSTALLATION

Continued

Apply pipe joint sealant lightly to male
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.

* Purchase the optional CSA/AGA design-certified equipment shutoff valve from your
dealer. See Accessories, page 27.

CSA/AGA Design-Certified Equipment
Shutoff Valve With 1/8" NPT Tap*

3" Minimum

From Gas
Meter (5"
W.C. to
10.5" W.C.
Pressure)

Approved Flexible
Gas Line

Pipe Nipple Cap Tee Joint

Sediment Trap

Figure 23 - Gas Connection

WARNING: This appliance re-

quires a 45

°

male flare fitting 5/8"-

18 UNF (Unified National Fine
Thread) inlet connection and the
flexible gas line provided.