beautypg.com

2 thermo well method, Thermo well method – Varec 4532 User Manual

Page 26

background image

Mounting

Average Temperature/Water Bottom Sensor and Converter

16

Installation and Operations Manual

5.2.2

Thermo well method

The flexible tube is inserted into a thermo well with a diameter of 2" or more.

Figure 5-5: Thermo well application

Caution!

The flexible tube must be lowered carefully without bending too much or scratching
at the inner edge of the nozzle hole.

1. Insert a gasket and lower the flexible tube into the inlet of the stilling well.
2. Rotate the 4532 ATC so that you can set up the cable in the most convenient way.
3. Fix the mounting flange of the 4532 ATC to the nozzle on the tank top using bolts.

Electrical compartment

Cable entry as specified

Flange

Flexible tube

approx.500 mm

From tank bottom to
element position #1

Clearance below

bottom hook

Ø26 mm(1.02")

400 mm (15.57")

(20")

Tank bottom

If the tank internal
pressure exceeds
1bar, fix the thermo
well in accordance
with below figure.

welding