beautypg.com

Vinotemp WINE-MATE VINO6500SSH User Manual

Page 14

background image

- 13 -

fan running
but
condensing
unit not
running

b. Failed

components


c. Low

refrigerant

b. Check start relay, start capacitor,

overload protector, compressor.

c. Call

service

13.Evaporator

freezing up

a. Evaporator air flow restriction
b. Condenser air flow restriction
c. Not stopping due to air leak, high

ambient temperature or low
temperature setting

d. Defective controller or probe
e. Low ambient temperature
f. Initially working then stopping,

moisture in the system

g. Refrigerant low or leaking
h. Expansion valve blockage

a. Check for fans and CFM
b. Check for fans and CFM
c. Check for seal, door opening,

ambient temperature and
temperature setting

d. Check for controller and probe
e. Change defrost cycle
f. Call

service


g. Call service
h. Call service

14.Water leak

a. Air leak in the wine cellar

(excessive condensate on the
front of the cooling unit)

b. High humidity
c. Evaporator air flow restriction or

low refrigerant

d. Water passages restricted
e. Drip tray leak (No water overflow

but water leak)

a. Check for any air leak


b. Use drain line
c. Check supply air flow or air TD

crossing evaporator

d. Clean the drip tray
e. Seal the leak using silicone sealant

15.Condensate

inside ducts

a. Drain line restricted
b. Continually running not stopping

c. Too cold supply air

a. Check for drain
b.

raise temperature setting or
increase defrost cycle

c.

Increase air flow or raise
temperature setting

16.Condensate

outside
ducts

a. Duct not insulated
b. High humidity
c. Too cold supply

a. Check for insulation
b. Use

dehumidifier

c.

Increase air flow or raise
temperature setting

17.Circuit

tripping

a. Incorrect fuse or breaker
b. Incorrect

wirings

c. Failed

components

a. Check for proper fuse or breaker
b. Check for wirings and connections
c. Call service

18.Noisy

operation

a. Mounting area not firm
b. Loose

parts



c. Compressor overloaded due to

high ambient temperatures or
airflow restriction

d. Defective

components

a. Add support to improve installation
b.

Check fan blades, bearings,
washers, tubing contact and loose
screws.

c. Check for airflow


d. Call service for checking internal

loose, inadequate lubrication and
incorrect wirings