UNVENTED NATURAL GAS FIREPLACE

®

INSTALLING GAS PIPING TO
FIREPLACE LOCATION

Installation Items Needed

Before installing fireplace, make sure you
have the items listed below.

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

* A CSA/AGA design-certified equipment
shutoff valve with 1/8" NPT tap is an accept-
able alternative to test gauge connection.
Purchase the optional CSA/AGA design-
certified equipment shutoff valve from your
dealer. See Accessories, pages 22 and 23.

WARNING: A qualified ser-

vice person must connect fire-
place to gas supply. Follow all
local codes.

WARNING: Never connect

fireplace to private (non-utility)
gas wells. This gas is commonly
known as wellhead gas.

CAUTION: Use only new,

black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of 1/2"
diameter or greater to allow
proper gas volume to fireplace. If
pipe is too small, undue loss of
pressure will occur.

Mantel Clearances for Built-In
Installation

If placing mantel above built-in fireplace,
you must meet minimum clearance between
mantel shelf and top of fireplace opening.

If your installation does not meet the below
minimum clearances, you must:

• raise the mantel to an acceptable height,

OR

• remove the mantel.

Figure 16 - Minimum Mantel Clearances for Built-In Installation

Installation must include an equipment
shutoff valve, union, and plugged 1/8" NPT
tap. Locate NPT tap within reach for test
gauge hook up. NPT tap must be upstream
from fireplace (see Figure 17, page 11).

INSTALLATION

Continued

Supplied Firebox
Hood Must Be
Used at All Times

Wire-mesh
Screen

Firebox

Noncombustible
Material May
Project Off this
Surface above
the Firebox Hood

Mantel Shelf

13" 16" 19" 21"

2

1

/2

"

6"

8"

10"

Note: All vertical
measurements are
from top of fireplace
hood opening to bottom
of mantel shelf.
These minimum
clearances replace any
other recommended
clearances supplied with
your ANS Z21.11.2
approved gas logs.

Wall board or facing
material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments or
other similar projec-
tions off of the facing
material.

Framing
Material

WARNING: This appliance re-

quires a 1/2" NPT (National Pipe
Thread) inlet connection to the
pressure regulator.