beautypg.com

Cleaning and maintenance, Trouble- shooting, Warning – Vanguard Heating VMH10TN User Manual

Page 24: Caution

background image

24

103670

CLEANING

AND

MAINTENANCE

ODS/PILOT AND BURNER

• Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air to clean.

Exterior

• Use a soft cloth dampened with a mild soap and water mixture. Wipe the

cabinet to remove dust.

TROUBLE-

SHOOTING

Note:

All troubleshooting

items are listed in order of
operation.

WARNING ICON

G 001

WARNING

Turn off fireplace and let cool before cleaning.

WARNING ICON

G 001

CAUTION

You must keep control areas, burner, and circulating air passage-
ways of fireplace clean. Inspect these areas of fireplace before each
use. Have fireplace inspected yearly by a qualified service person.
Fireplace may need more frequent cleaning due to excessive lint
from carpeting, bedding material, etc.

POSSIBLE
CAUSE

1. Ignitor cable pinched or

wet

2. Ignitor electrode not con-

nected to ignitor cable

3. Broken ignitor cable
4. Bad piezo ignitor
5. Ignitor electrode broken
6. Ignitor electrode posi-

tioned wrong

REMEDY

1. Free ignitor cable if

pinched by any metal or
tubing. Keep ignitor
cable dry

2. Reconnect ignitor cable

3. Replace ignitor cable
4. Replace piezo ignitor
5. Replace ignitor
6. Replace ignitor

OBSERVED
PROBLEM

When ignitor button
is pressed, there is no
spark at ODS/pilot

WARNING ICON

G 001

WARNING

Turn off and unplug fireplace and let cool before servicing. Only a
qualified service person should service and repair fireplace.

WARNING ICON

G 001

CAUTION

Never use a wire, needle, or similar object to clean ODS/pilot. This
can damage ODS/pilot unit.