beautypg.com

Installing, Continued – Vanguard Heating VMH10TN User Manual

Page 13

background image

13

103670

INSTALLING

Continued

Continued

5. Carefully set fireplace in front of rough opening with back of fireplace inside

wall opening.

6. Attach flexible gas line to fireplace gas regulator. See Connecting Fireplace to

Gas Supply, page 17.

7. If the optional blower has been installed connect blower to electrical source.

Options one and two:

Route blower electrical cord through side or rear

access door of fireplace. Plug electrical cord into electrical outlet.

Option two:

Have a licensed electrician connect blower to electrical source

at junction box inside fireplace.

8. Bend four nailing flanges on outer casing with pliers (see Figure 10).

9. Attach fireplace to wall studs using nails or wood screws through holes in

nailing flange.

10. Check all gas connections for leaks. See Checking Gas Connections, page 17.
11. If using optional brass trim kit, install the trim after final finishing and/or

painting of wall. See instructions included with brass trim accessory for attach-
ing brass trim.

Figure 10 - Attaching Fireplace to Wall Studs

Mantel Clearances for Built-In Installation

If placing mantel above built-in fireplace, you must meet minimum clearance
between mantel shelf and top of fireplace opening.

Nailing
Flanges

Nails or Wood
Screws

Distances to
Underside of
Built-in Mantel

Underside of
Mantel Shelf

20"

24

1/2

"

27

1/2

"

30"

All minimum
distances are
in inches

Top of
Fireplace
Opening

2

1

/2

"

6"

8"

10"

If your installation does not meet the above minimum clearances, you must:
• raise the mantel to an acceptable height, OR
• remove the mantel.

Figure 11 - Minimum Mantel Clearances for Built-In Installation

Mantel Shelf

Side of
Firebox