Features and operation, Installation – Vanguard VE36L User Manual
Page 7
www.desatech.com
115121-01B
7
INSTALLATION
Continued
LAMPS AND LAvA ROCk
Before operating fireplace, lamp bulbs must
be inspected and lava rock may be added if
desired.
1. Lift log bed off hearth base to gain access
to lamp fixtures (log bed is attached with
contact magnets).
2. Turn on power to light circuit and check
that all bulbs are operating. Bulb place-
ment front left to right are red, yellow and
orange (see Figure 12).
Note: If bulbs need replacing, see Replac-
ing Light Bulbs, page 15. Be careful not to
tear or damage reflective strips. If they have
come loose, ends can be easily reattached or
replaced at support brackets. See Replacing
Reflective Ribbons, page 19.
3. Center log bed over opening between
viewing panel screen and grate.
4. Cover remaining hearth area with 1/4" of
lava rock (provided), if desired.
FEATURES AND
OPERATION
This electronic fireplace series features a
random flame effect, and a realistic log bed
with glistening embers that can be adjusted
for flame speed and light intensity. VE36/32LH
models have a circulating heater, rated at
1100 Watts. Models VE36/32LB and VE36/
32LBH include a hand detailed, textured,
red-brick lining.
Access controls by pulling two handle tabs
of upper louver until panel releases from
magnetic catches and swings down to open
position (see Figure 13).
Figure 14, page 8, shows control layout for
heater equipped models with main power
switch to flame controls and heater power
switch (when equipped) to heating unit. This
allows independent and efficient operation of
both features.
Once main power is turned on, flame speed
and brightness may be turned on and adjusted
independently.
Figure 11 - Removing Shipping Brace
Foam
Shipping
Brace
Figure 12 - Bulb Placement
Red
Yellow
Orange
Log Bed
Figure 13 - Accessing Controls
Motor
Mount
Grate
Viewing Panel