Product specification, Installation, Locating fireplace – Vanguard VE36L User Manual

Page 3: Figure 1 - unit dimensions

background image

www.desatech.com

115121-01B

3

PRODUCT SPECIFICATION

VE32 = 15

5

/

8

"

VE36 = 17"

VE32 = 16

1

/

4

"

VE36 = 17

5

/

8

"

VE32 = 22

1

/

4

"

VE36 = 24

1

/

4

"

VE32 = 29

3

/

8

"

VE36 = 35"

VE32 = 7"
VE36 = 8"

VE32 = 6

1

/

2

"

VE36 = 5

1

/

4

"

VE32 = 18

3

/

8

"

VE36 = 21"

VE32 = 33

3

/

8

"

VE36 = 37"

VE32 = 36

3

/

8

"

VE36 = 43"

VE32 = 35

3

/

8

"

VE36 = 42"

VE32 = 34

5

/

8

"

VE36 = 41

1

/

4

"

VE32 = 32

5

/

8

"

VE36 = 36

1

/

4

"

VE32 = 28

3

/

8

"

VE36 = 31

3

/

4

"

VE32 = 32

7

/

8

"

VE36 = 36

1

/

2

"

1

7

/

8

"

5/8"

TOP

FRONT

LEFT SIDE

RIGHT SIDE

VE32 = 32

1

/

8

"

VE36 = 36

1

/

8

"

VE32 = 28

3

/

8

"

VE36 = 31

3

/

4

"

To

Nail

Location

To Nail
Location

VE32 = 8"
VE36 = 5

1

/

4

"

ELECTRICAL SPECIFICATIONS
Voltage:

120 VAC, 60 Hz

Total Amps:

12.5 Amps

Total Watts:

1500 Watts

Heater Rating:

1100 Watts

Max. Bulb Rating:

100 Watts

Use only on 15 amp circuit

Figure 1 - Unit Dimensions

INSTALLATION

LOCATING FIREPLACE

Plan where to locate and frame fireplace.
Before installation consider the following:
1. Fireplace location must allow for wall and

ceiling clearances (see Installation Clear-
ances
, page 4).

2. Fireplace screen should not be exposed

to direct sunlight from windows or doors.

3. A 15 amp, 120 Volt, 60 Hz circuit with

proper ground must be available. A dedi-
cated circuit should be provided to avoid
circuit breaker trips or blown fuses.

Prefab Mantel Installations are not perma-
nent and are low cost and easy to install on an
open wall space or a corner with an accessible
electrical outlet.
Flush Installations are recommended where
living space is limited or at a premium. Since
the space required to enclose the fireplace
would be located beyond an outside wall, this
installation would require additional planning
and construction. Check local codes for any
restrictions.

Projected Installations can extend any
distance into the room. A projection may
be ideal for a new addition on an existing,
finished wall.
Corner Installations make use of space
that may not normally be used and provides
a wider and more efficient viewing angle and
heat distribution.
Internal Wall Installations provide a discrete
option for room separation and can also be an
ideal addition to an existing wall.

Figure 2 - Possible Installation Locations

Internal Wall

Installation

Full Projection

Installation

Flush

Installation

Corner

Installation