ELECTRICAL INSTALLATION

WARNING: Any electrical re-

wiring of this appliance must be

done by a qualified electrician.

This wiring must be done in ac-

cordance with local codes and/or

in the U.S.A. with the current, Na-

tional Electrical Code ANSI/NFPA

No 70 and in Canada with CSA

C22.1 Canadian Electric code.

This fireplace should be con-

nected to a dedicated 15 Amp,

circuit as other appliances may

cause the circuit breaker to trip

or fuse to blow when fireplace

is in operation.

A junction box with universal strain adaptor
is provided to hard wire unit to a 15 amp,
120 Volt 60 Hz grounded circuit. Power cord
must first be removed and universal strain
relief bushing inserted into junction box cover
before connecting supply line (see Figure 7,
page 5). If necessary, junction box may be
relocated to route supply to left side.
1. Remove 2 screws and outer cover on right

side (see Figure 10).

2. Remove inner screw securing junction

box.

3. Slide junction box up until mounting tab

is lined up to notch in outer cabinet.

4. Swing box out and slip retaining flange

out through slot in outer cabinet.

5. Remove 2 screws and outer cover on left

side and reattach on right side of outer
cabinet.

6. Swing junction box with harness to left

side while pulling sufficient length of har-
ness out through control panel cover to
reach mounting location on left side.

7. Reinsert retaining flange through slot and

swing screw mounting tab back through
notch as before.

8. Slide junction box down until mounting

holes line up and replace inner retaining
cover.

9. Pull end of 3 wire Romex supply line

through universal strain relief bushing in
remaining cover.

10. Strip back outer Romex to about 4” and

connect black, white and green wires ac-
cordingly using approved connectors.

11. Tuck tailing wires into junction box and

replace cover using 2 remaining screws.

12. Tighten down strain adjustment on uni-

versal bushing until Romex sheathing is
secured.

IMPORTANT: Inspect components and wir-
ing for damage before connecting power to
unit. If any components are found damaged,
contact an authorized dealer for original DESA
replacement part(s) or call DESA at 1-866-
872-6040 for referral.
IMPORTANT: Prior to operation remove foam
shipping brace located under motor mount
(see Figure 11, page 7).

Screws
and
Outer
Cover

Junction Box

Mounting
Tab

Notch

Retaining
Flange

Slot

Screws and
Outer Cover
from Other Side

Cover with
Universal
Strain Relief

Figure 10 - Relocating Junction Box to

Left

INSTALLATION

Continued

Junction Box