Alarm out, Record start in, Alarm record reset – Vista 0150-0267A User Manual

Page 9: Vext pulse out, Error out

background image

0150-0267A

1-5

Vista Solo

Alarm Out

The Alarm output is activated while the Alarm Input is active.
The Alarm output is only active for the duration of the alarm
event.

Output: Active Low
High: 12V
Low: Ground
Current Out: 50mA Max
Short Circuit Protected.

Low for duration of alarm.

Record Start In

Record Start In will place the unit in Record mode when
activated. Compatible with the Disk End Out signal from a
second unit.

Input: Active Low TTL w/ pull-ups
or Normally Open Relay.
High: 5V (12V tolerant)
Low: Ground

Minimum Duration: 0.5 Seconds

Alarm Record Reset

This feature is for future development, and has not yet been implemented.

VEXT Pulse Out

Output: Active Low
High: 5V
Low: Ground (0.8V Max)
Current Out: 50mA Max
Short Circuit Protected.

The Video External Pulse connection (VEXT) simplifies
multiplexer operation by automatically synchronizing the
Multiplexer and the Vista Solo.

The Vista Solo sends a VEXT pulse to the Multiplexer indicating
that it is ready to record the next image. The Multiplexer
responds by sending the next image to the Video Input on the
Vista Solo.

The VEXT connection is especially beneficial for units
configured with dual record speeds (Normal and Alarm).

Use of the VEXT connection is Highly Recommended when
connecting the unit to a multiplexer.

Error Out

The Error Out signal is activated when the unit experiences any
operational or internal error.

Output: Open Collector
High: Transistor Off
Low: Transistor On
Active When On.
Current Out:
10mA Max

Minimum Duration: 0.5 Seconds