Ventilation, Installation requirements, Built-in island/classic chimney island hood – Viking VCIH User Manual

Page 4

background image

VIH Professional

Island Hood

VCIH Professional Classic

Chimney Island Hood

DCIH Designer Chimney

Island Hood

Proper installation/ducting is extremely
important to ensure maximum
performance. Use a qualified and
trained installer.

DUCTING
• Check with a qualified and

trained installer or local codes
for makeup air requirements,
if any.

• Max. duct run

o For 300 – 1,200 CFM—50’

(152.4 m)

o For 1,500 CFM—75’ (22.9 m)
o Duct run length is for general

reference only; for longer
duct runs, increase duct size
and contact a qualified and
trained installer.

o Straight runs and gradual

turns are best; for example,
each 90° elbow is equivalent
to 5’ – 10’ (1.52 – 3.05 cm) of
straight run.

• 7” (17.8 cm) round duct for

300 – 600 CFM; 10” for 900 –
1500 CFM

o Never use flexible duct; it

creates back pressure/air
turbulence and greatly
reduces performance.

GAS
Not applicable

ELECTRICAL
• Hardwire direct with two-wire

with ground

• 120 VAC/60 Hz
• Max. amp usage (rating

includes rec. ventilator kit
rating)

PLUMBING
Not applicable

P L A N N I N G A N D D E S I G N G U I D E

V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1

R E L E A S E D 1 2 / 1 / 0 7

© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE

VENTILATION

Built-In Island/Classic Chimney Island Hood

Installation Requirements

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs.

Note: Maximum amp rating for hoods includes recommended ventilator kit rating. All products must be hard wired with two-wire ground. An interior- or
exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.

Model

Ventilator Kits

Duct Size

Max. Amps

Interior

Exterior

Interior

Exterior

Interior

Exterior

VIH3608

VIV600/1200*

VEV900/1200*

7” (17.8 cm)/

10” (25.4 cm)

4.9/7.4

7.4/4.7

10” (25.4 cm)

VIH4208

VIV600/1200*

VEV900/1200/1500*

7” (17.8 cm)/

10” (25.4 cm)

4.9/7.4

7.4/4.7/5.5

10” (25.4 cm)

VIH5408

VIV1200*

VEV1200/1500**

10” (25.4 cm)

10” (25.4 cm)

8.2

5.5/6.2

VIH6608

VIV1200*

VEV1200/1500**

10” (25.4 cm)

10” (25.4 cm)

8.2

5.5/6.2

VCIH3608

DIV600*

DEV900/1200*

7” (17.8 cm)

10” (25.4 cm)

3.9

6.6/3.9

VCIH4208

DIV600*

DEV900/1200/1500*

7” (17.8 cm)

10” (25.4 cm)

4.7

7.4/4.8/5.5

VCIH5408

DIV1200*

DEV1200/1500**

10” (25.4 cm)

10” (25.4 cm)

8.6

5.6/6.4

VCIH6608

DIV1200*

DEV1200/1500**

10” (25.4 cm)

10” (25.4 cm)

9.5

6.5/7.3

DCIH3604

DIV600

DEV900/DEV1200*

7” (17.8 cm)

10” (25.4 cm)

4.7

8.6

DCIH4204

DIV600

DEV1200/DEV1500**

7” (17.8 cm)

10” (25.4 cm)

4.7

7.4/4.7/5.5

DCIH5404

DIV1200*

DEV1200/DEV1500**

10” (25.4 cm)

10” (25.4 cm)

8.6

5.6/6.4

Note: All CFMs are based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be
greatly overstated.