Status LEDs

There are two status LEDs on the front of your Micro Chip Display Projection TV.

Normal Operation

State

Power LED Lamp LED Description

AC off

Not lit Not lit

AC power not connected

Standby mode

Orange Not lit AC power is connected and

your RPTV is in standby

mode.

Warm-up

Blue Orange Flashing AC power is connected and

the power button has just been

turned

on.

Cool down

Orange Orange Flashing Powering off.

Operation mode

Blue Not lit AC power is connected, the

power button has been

pressed, and the lamp has

warmed up.

Error Codes

Error

Code

Power LED

Lamp LED

Description

21

Flashes blue twice,

then orange once.

Not lit

One of the cooling fans has failed.

See “Support” on page 49.

32

Flashes blue three

times, then orange

twice.

Flashing

Lamp trouble or failure. Your RPTV

automatically shut down and

restart itself. If this does not solve

the problem, see “Support” on

page 49.

52

Flashes blue five

times, then orange

twice.

Not lit

Hardware error. Shut off your

RPTV, wait one minute, then

restart your RPTV. If this does not

solve the problem, see “Support”

on page 49.